Suggestions
new
Controller DULCOMETER® diaLog DACa/DACb

Do you wish a simple controller for water analysis? One that is easy to operate and with which you can freely select between all common measured variables per channel? There is one: our all-rounder DULCOMETER® diaLog DACa/DACb! What is more, it is Ethernet-/LAN-capable and can be ideally integrated into existing networks.

Product description

Water parameter analysis made easy – with the DULCOMETER® diaLog DACa/DACb

The controller DULCOMETER® diaLog DACa/DACb is our compact all-rounder for water analysis. With its specially designed functionalities, e.g. processing or interference variables and switchover of control parameters, it closes the control circuit between DULCOTEST® sensors and ProMinent® metering pumps. The two measuring and control channels of the DULCOMETER® diaLog DACa/DACb can be individually configured to meet customer requirements. Everything that you need for the reliable treatment of industrial and process water, potable water or even swimming pool water.

Your benefits

  • Simple operation thanks to a clearly arranged display
  • More for your money: two measuring and control channels now in the basic configuration -> available from 2nd quarter of 2017 as the DACb version
  • Versatile use: all common measured variables can be set per channel and subsequently altered
  • Control from everywhere: LAN-capable and convenient remote access via integrated web server
  • Maximum flexibility: individually adjustable to different operating statuses, e.g. Day-Night mode
  • Excellent process safety and reliability: avoidance of incorrect metering by time-based monitoring of control variables

Field of application

  • Measurement and control of water parameters in industrial and process water treatment plants
  • Monitoring of the water parameters potable water
  • Measurement of pH value and disinfection parameters in the food and beverage industry
  • Measurement and control of the hygiene parameters in swimming pools
  • Monitoring of the chlorine dioxide concentration in systems for legionella control and prevention, for example in schools, hotels or hospitals
  • Measurement of the disinfection parameters of irrigation and sprinkler irrigation water in market gardens
    1 2 3 4 5 6 7 8 9

    Technical Details

    • Measured variables: pH, ORP, chlorine, chlorine dioxide, chlorite, bromine, conductivity, peracetic acid, hydrogen peroxide, ozone, dissolved oxygen and fluoride
    • Method of installation, degree of protection: Combination housing (wall mounting, control panel mounting, pillar assembly) IP 67 and IP 66
    • Control: two measuring and control channels, each with independent monodirectional PID controller (optional: two bidirectional PID controllers) -> available from 2nd quarter of 2017 as the DACb version
    • 24 V DC protective low voltage supply e.g. by means of solar system or in the set are of waterworks -> available from 2nd quarter of 2017 as the DACb version
    • Temperature compensation for pH and for chlorine dioxide process sensor CDP, pH compensation for chlorine
    • Digital inputs for the processing of control signals, e.g. of process water limit contacts, remote stop control and to monitor the liquid levels in chemical storage tanks
    • Control outputs for electronically controlled metering pumps and solenoid valves
    • Interference variable processing: simple control of water parameters in flowing water by processing the flow in the control algorithm
    • Adaptation of the controller setpoint to changed process conditions is possible via remote control by means of the mA signal of a Programmable Logic Controller (PLC) or with higher requirements via the field bus option
    Measuring range

    mV connection type:

    pH: 0.00 ... 14.00

    ORP voltage: -1500 ... +1500 mV

    Connection type mA (amperometric measured variables, measuring ranges corresponding to the sensors):

    Chlorine

    Chlorine dioxide

    Chlorite

    Bromine

    Ozone

    Hydrogen peroxide (PER sensor)

    Hydrogen peroxide (PEROX sensor with PEROX transducer V2 Order No. 1047979)

    Peracetic acid

    Dissolved oxygen

    Connection type mA (potentiometer measured variables, measuring ranges corresponding to the transmitter):

    pH

    ORP voltage

    Fluoride

    Conductivity (measuring ranges corresponding to the transmitters):

    via Transmitter 0/4 ... 20 mA

    Temperature:

    via Pt 100/Pt 1000, measuring range 0 ... 150 °C

    Resolution

    pH: 0.01

    ORP voltage: 1 mV

    Temperature: 0.1 °C

    Amperometric analysis (chlorine etc.): 0.001/0.01 ppm, 0.01 vol.%, 0.1 vol.%

    Accuracy0.3% based on the full-scale reading
    Measurement inputpH/ORP (input resistance > 0.5 x 1012 Ω)
    Temperature compensationPt 100/Pt 1000 for pH, chlorine dioxide (CDP) sensor and fluoride
    Correction range0 … 100 °C
    pH compensation range for chlorineSensor CLE 3 and CLE 3.1: 6.5 ... 8.5, sensor CBR: 6.5 ... 9.5
    Disturbance signalsFlow via 0/4 … 20 mA or contact water meter 1 - 500 Hz, the interference variable acts on both channels
    Control characteristicP/PID control
    Control2 x bidirectional control
    Analogue outputs2 (3) x 0/4 ... 20 mA electrically isolated, max. load 450 Ω, range and assignment (measured, correction, control variable) can be set
    Control outputs

    2 x 2 pulse frequency outputs for metering pump control

    2 relays (limit value, 3-point step or pulse length control)

    Alarm relay250 V ~3 A, 700 VA contact type changeover contact
    Digital control inputs2 (5) as a remote control input for the functions pause control / sample water fault, parameter set switch-over, level monitoring of chemical tanks
    Electrical connection90 – 253 V, 50/60 Hz, 25 VA, 24 V DC
    Field bus connectionPROFIBUS®-DP, Modbus RTU
    Ambient temperature

    0 ... 50°C (for use indoors or with a protective enclosure)

    Enclosure rating

    Wall-mounted: IP 66 and IP 67 (NEMA 4X)

    Installation in the control cabinet: IP 54 for control cabinet door

    Tests and approvalsCE, MET (corresponding to UL according to IEC 61010)
    Housing materialPC with flame proofing equipment
    Dimensions250 x 220 x 122 mm (WxHxD)
    Weight1.3 kg

    Standard equipment of the 1-channel design

    • Measuring channel 1 with 14 freely selectable measured variables (via mV or mA). The measured variables conductive or inductive conductivity are provided by the Compact controllers COND_C (conductive) and COND_I (inductive).
    • PID controller with pulse frequency-based metering pump control for 2 metering pumps.
    • 2 analogue outputs for measured value, correction value or control variable (dependent on the optional equipment).
    • 2 digital inputs for sample water fault detection, pause and parameter switch-over.
    • 2 output relays selectable as limit value, cycle timer, real-time timer or intermittent programmable control output (depending on the optional equipment).
    • Measured variables and language selection during commissioning.
    • Temperature compensation of the pH, chlorine dioxide (CDP) and fluoride measurement via Pt100/Pt1000.
    • 22 operating languages: all European languages as well as Chinese, Russian, Thai, Korean. The operating language is selected during commissioning and can be changed at any time by a keyboard shortcut. The documentation language is selected via the identity code. A data carrier is also supplied that contains all other languages.
    • Saving and transfer of device parameterisation by means of the SD card.
    • Calibration and event data logger (without SD card, data is saved in the controller).
    • Interference variable processing (flow) via frequency (contact water meter).
    • Subsequent upgrade of the software function by means of an activation key or firmware update.

    Optional equipment of the 2-channel design

    Package 2

    • Interference variable processing (flow) via mA, or
    • pH compensation for chlorine with pH control, or
    • External remote setpoint via an analogue signal for channel 1.

    Package 3

    • Second, complete measuring and control channel with PID controller (replaces the D2Ca controller).
    • 3rd analogue output for measured value, correction value or control variable (depending on the optional equipment).
    • 3 additional digital inputs, e.g. for level monitoring, pause and sample water alarm for channel 2.
    • Temperature compensation of the pH, chlorine dioxide (CDP) and fluoride measurement.

    Package 4

    • Combination of packages 2 and 3 (only one channel for amperometric sensors is available with the interference variable mA).

    Communication options

    • Measurement data logger with SD card
    • Visualisation of the measured data using a web server via LAN or WLAN and a PC/tablet PC and web browser
    • PROFIBUS®-DP, Modbus RTU

    Hardware extension

    • Protective RC circuit for output relay: Protects the output relay if inductive loads are to be switched (e.g. solenoid valves or motors). Not with 24 V DC electrical connector.

    Note: The controller DULCOMETER® diaLog DACa will be replaced by the DULCOMETER® diaLog DACb at latest by the 2nd quarter of 2017.

    Downloads for Controller DULCOMETER® diaLog DACa/DACb

    load more of

    Overview

    Water parameter analysis made easy – with the DULCOMETER® diaLog DACa/DACb

    The controller DULCOMETER® diaLog DACa/DACb is our compact all-rounder for water analysis. With its specially designed functionalities, e.g. processing or interference variables and switchover of control parameters, it closes the control circuit between DULCOTEST® sensors and ProMinent® metering pumps. The two measuring and control channels of the DULCOMETER® diaLog DACa/DACb can be individually configured to meet customer requirements. Everything that you need for the reliable treatment of industrial and process water, potable water or even swimming pool water.

    Your benefits

    • Simple operation thanks to a clearly arranged display
    • More for your money: two measuring and control channels now in the basic configuration -> available from 2nd quarter of 2017 as the DACb version
    • Versatile use: all common measured variables can be set per channel and subsequently altered
    • Control from everywhere: LAN-capable and convenient remote access via integrated web server
    • Maximum flexibility: individually adjustable to different operating statuses, e.g. Day-Night mode
    • Excellent process safety and reliability: avoidance of incorrect metering by time-based monitoring of control variables

    Application

    Technical Data

    Downloads

    Contact us

    Stephen Ellix

    Managing Director, ProMinent Fluid Controls UK Ltd.

    »We are always available to help. Don't hesitate to contact us.«

    +44 1530 560 555  Send request   

    Close Form

    Your Request

    Personal Information


    Further product +
    Attachment
    Upload Next file

    Personal Information


    Please fill in all mandatory fields.
    *Mandatory fields

    Check and Send


    Personal Information:
    Salutation
    Title
    Last name  
    First name  
    Company
    Customer ID
    E-mail address
    Phone
    Street
    House no.
    City  
    Country
    Callback Yes

    Back

    Matching Products

    1 2 3 4 5 6 7 8 9 10 11