Suggestions

Electrolysis System CHLORINSITU V

Output 100 – 3,500 g/h of chlorine

Electrolysis systems of type CHLORINSITU V generate ultra-pure chlorine gas directly on site and only need salt, water and electricity to do so. They are especially well suited to disinfecting drinking water, waste water, process water and water in swimming pools and cooling towers.

Product description

Chlorine produced from common salt. Directly on site. For clean and safe disinfection.

Electrolysis Chlorine and sodium hydroxide are produced in-situ in electrolysis by passing an electric ... more in the glossary systems of type CHLORINSITU V generate ultra-pure chlorine gas and sodium hydroxide solution free of chloride as required and on site. The disinfection solution is produced in a vacuum process Process which allows high-purity substances (e.g. active chlorine) to be generated through the absence of oxygen and other gases. more in the glossary from safe raw materials (salt and water); no dangerous chemicals have to be transported or stored, making the process particularly safe.

The disinfection solution is very clean – it contains only minimal quantities of chloride and chlorate - yet is highly effective.

Function

A saturated sodium chloride solution that is electrolysed in a membrane cell is produced in a salt-dissolving tank. Ultra-pure chlorine gas and diluted residual Describes the ability of a substance to have a long-term effect and ... more in the glossary brine are produced in the anode chamber as part of this process. The chlorine gas produced is suctioned off through an injector (vacuum system) and is fully dissolved as hypochlorous acid in the water being treated. The chlorinated water can be used to disinfect several pools via one or more controllable motor-driven ball valves. The residual Describes the ability of a substance to have a long-term effect and ... more in the glossary brine is discarded.

The sodium hydroxide solution produced in the cathode chamber is stored temporarily and can be used for pH correction. The hydrogen produced is diluted with fresh air by a fan and discharged safely.

Your benefits

  • Chlorination and pH adjustment with a single system
  • Exceedingly low chloride and chlorate content
  • Production and metering of high-purity hypochlorous acid without temporary storage
  • Hypochlorite booster for peaks in demand (Plus system)
  • Safe system control with remote diagnosis by Remote Control Engineer
  • Excellent service life of the membrane cells thanks to a constant vacuum

Technical Details

  • Modern PLC with large display
  • Integrated Remote Control Engineer for remote diagnosis and troubleshooting
  • Chlorine metering and pH value correction controlled via contact inputs
  • Analogue input (optional)
  • Modbus or PROFIBUS® (optional)
  • Several points of injection (optional)
  • Multiple booster pumps (optional) can be used for different water qualities (e.g. brine and freshwater pools)

Technical Data

Type/output

Fuse

Power uptake

Salt consumption

Max. consumption of process water

Consumption of cooling water (external)

Dimensions L x W x H

Brine tank

g/h

A

kW

kg/d

l/h

l/h

mm

l

100

3 x 16

1.10

5

60

-

1,655 x 600 x 1,550

210

200

3 x 16

1.50

10

60

-

1,655 x 600 x 1,550

210

300

3 x 16

1.90

15

60

-

1,655 x 600 x 1,550

210

400

3 x 16

2.30

20

60

-

1,655 x 600 x 1,550

210

500

3 x 16

2.70

25

60

-

1,655 x 600 x 1,550

210

600

3 x 20

3.10

30

90

-

1,950 x 600 x 2,000

400

750

3 x 25

3.70

35

90

-

1,950 x 600 x 2,000

400

1,000

3 x 25

4.70

50

90

-

1,950 x 600 x 2,000

400

1,250

3 x 35

5.70

60

90

-

1,950 x 600 x 2,000

400

1,500

3 x 35

6.70

70

90

-

1,950 x 600 x 2,000

400

1,750

3 x 35

7.70

80

90

-

1,950 x 600 x 2,000

400

2,000

3 x 50

8.70

100

175

200

1,750 x 1,200 x 2,000

520

2,500

3 x 63

10.70

150

175

300

1,750 x 1,200 x 2,000

520

3,000

3 x 63

12.70

175

175

350

1,750 x 1,200 x 2,000

520

3,500

3 x 80

14.70

175

175

250

1,750 x 1,200 x 2,000

520

Capacities > 3,500 g/h upon request

Scope of delivery:

Electrolysis systems of type CHLORINSITU V are ready mounted, wired for use, on a powder coated stainless steel frame with a Programmable Logic Controller (PLC) in the control cabinet, Remote Control Engineer for remote diagnosis and troubleshooting, integrated water softening unit, membrane electrolysis cells, hydrogen bleed system and separate salt dissolving tank with level monitoring. The scope of delivery also includes a frequency-controlled central injector system matched to the system to meter active chlorine and sodium hydroxide solution for pH correction and a single booster pump. A chlorine gas warning unit and automatic monitoring of water hardness downstream of the softening system come as standard with systems producing more than 600 g/h.

Remark

Electrolysis systems of type CHLORINSITU II, III, V and V Plus are available and planned to meet customer specifications. This is true both for the system documentation and the subsequent supply of spare parts and maintenance.

Downloads for Electrolysis System CHLORINSITU V

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by A to Z
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

Chlorine produced from common salt. Directly on site. For clean and safe disinfection.

Electrolysis Chlorine and sodium hydroxide are produced in-situ in electrolysis by passing an electric ... more in the glossary systems of type CHLORINSITU V generate ultra-pure chlorine gas and sodium hydroxide solution free of chloride as required and on site. The disinfection solution is produced in a vacuum process Process which allows high-purity substances (e.g. active chlorine) to be generated through the absence of oxygen and other gases. more in the glossary from safe raw materials (salt and water); no dangerous chemicals have to be transported or stored, making the process particularly safe.

The disinfection solution is very clean – it contains only minimal quantities of chloride and chlorate - yet is highly effective.

Function

A saturated sodium chloride solution that is electrolysed in a membrane cell is produced in a salt-dissolving tank. Ultra-pure chlorine gas and diluted residual Describes the ability of a substance to have a long-term effect and ... more in the glossary brine are produced in the anode chamber as part of this process. The chlorine gas produced is suctioned off through an injector (vacuum system) and is fully dissolved as hypochlorous acid in the water being treated. The chlorinated water can be used to disinfect several pools via one or more controllable motor-driven ball valves. The residual Describes the ability of a substance to have a long-term effect and ... more in the glossary brine is discarded.

The sodium hydroxide solution produced in the cathode chamber is stored temporarily and can be used for pH correction. The hydrogen produced is diluted with fresh air by a fan and discharged safely.

Your benefits

  • Chlorination and pH adjustment with a single system
  • Exceedingly low chloride and chlorate content
  • Production and metering of high-purity hypochlorous acid without temporary storage
  • Hypochlorite booster for peaks in demand (Plus system)
  • Safe system control with remote diagnosis by Remote Control Engineer
  • Excellent service life of the membrane cells thanks to a constant vacuum

Application

Technical Data

Downloads

Contact us

Wesley Sutton

Managing Director, ProMinent Fluid Controls UK Ltd.

»We are always available to help. Don't hesitate to contact us.«

+44 1530 560 555  Send request   

Matching Products

1 2

ProMinent Newsletter - receive latest news, customized for you! subscribe now