Suggestions

Motor-Driven Metering Pump Sigma X Control Type – Sigma/ 2 - S2Cb

Capacity range S2Cb: 61 – 353 l/h, 16 – 4 bar

The Sigma control type is a smart motor-driven metering pump that is setting new standards in terms of productivity, reliability and safety.

Product description

The new Sigma X family – reliable, smart and with scope for networking

The Sigma X diaphragm metering pump covers a capacity range of 21 to 1,040 l/h in versions S1Cb, S2Cb and S3Cb. Its patented multi-layer safety diaphragm guarantees maximum process reliability. Efficient protection of the power end from overloading by means of an integral frequency converter with microprocessor control(ler).

One highlight is the standardised operating concept with click wheel and 4 additional operating keys on a removable operating unit. A large illuminated LCD and a 3-LED display for operating, warning and error messages, visible from all sides, offers additional operating convenience.

The Sigma, like all smart ProMinent metering pumps, can be flexibly connected to various bus systems.

It has a large adjustment range thanks to a combination of frequency and stroke length adjustment. The pump works with high precision across the entire frequency range. Accurate and complication-free metering of viscous and gaseous media by adjustment of the movement profile.

Operating statuses are simply remotely transmitted via an additional output or relay module. A built-in timer, included as standard, controls time-dependent metering cycles.

Relevant spare parts can be shown in the display. The integral log book significantly improves process management, optimisation and troubleshooting.

Your benefits

  • Safe: In the event of an accident, the feed chemical does not escape to the outside nor into the pump's power end, thanks to the patented multi-layer safety diaphragm with optical (optionally electric) signalling.
  • Integrated overload shut-down in the pump control to protect the pump from overloading and thus significantly reduce pressure surges caused by blockages.
  • External control is scalable via potential-free contacts with pulse step-up and step-down, batch mode or via a 0/4-20 mA standard signal.
  • Flexibly connectible: Connection to process management systems via integral PROFIBUS®, CANopen interface.
  • Integral log book saves up to 300 events and simplifies troubleshooting and analysis of the cause.
  • Sigma X Family - Module 1 - Introduction

  • Sigma X Family - Module 2 - higher efficiency

  • Sigma X Family - Module 3 - higher reliablilty

  • Sigma X Family - Module 4 - variable metering profiles

  • Sigma X Family - Module 5 - flexible in use

Field of application

  • All industrial applications, either as a stand-alone unit or integrated in a complete system
  • Volume-proportional addition of chemicals in water treatment, e.g. sodium hypochlorite for the disinfection of potable water
  • Neutralisation in waste water treatment
  • Pulse-controlled metering in the bottling of different volumes e.g. glycerol filling of manometers
  • With an integrated timer as a control unit for simple processes, e.g. biocide metering in cooling water
    1 2 3 4 5 6 7 8 9 10 11

    Technical Details

    • Stroke length: 5 mm
    • Stroke length adjustment range: 0 – 100%
    • Stroke length adjustment: manually using self-locking rotary dial in 1% increments
    • Metering reproducibility is better than ± 2% in the 30 – 100% stroke length adjustment range under defined conditions and with correct installation
    • Power supply: 1 pH, 100 – 230 V ±10%, 240 V ±6%, 50/60 Hz (110 W)
    • Degree of protection IP 65
    • Fibreglass-reinforced plastic housing
    • Settable manual or external contact mode, factor with external contact control 99:1 – 1:99; batch mode with max. 99,999 strokes/start pulse.
    • Display of wear parts in the Service menu.
    • Connector for 2-stage level switch.
    • Connection to PROFINET using the ProMinent DULCOnvert PROFIBUS®-PROFINET converter.
    • Time-dependent control of the metering volume via integral timer.
    • Relay module with 1 x switchover contact, 230 V – 8 A
    • Relay module with 2 x On, 24 V – 100 mA
    • Output / relay module: 0/4- 20 mA analogue output for remote transmission of the stroke rate plus relay module with 1 x On, 24 V – 100 mA
    • The Sigma product range is available in a "Physiologically safe in respect of wetted materials" design.
    • Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
    • Dosing heads with electro-polished stainless steel are available for aqueous media with hygienically demanding applications.
    • Customised designs are available on request.

     For reasons of safety, provide suitable overload protection mechanisms when installing all mechanically deflected diaphragm metering pumps.

    Technical Data

    Type

    Capacity at max. back pressure

    Max. stroke rate

    Capacity at max. back pressure

    Suction lift

    Perm. pre-pressure suction side

    Connector Suction/Discharge Side

    Shipping weight

    S2Cb

    bar

    l/h

    ml/stroke

    Strokes/min

    psi

    gph (US)

    m WC

    bar

    G-DN

    kg

    * For the Sigma types 07120, 07220 and 04350, the dosing head is fitted with DN 25 (G 1 1/2) valves. As DN 20 is generally sufficient for the pipework for these types (see technical data, suction/discharge side connector), the connector parts that can be ordered with the identity code (e.g. inserts) are already reduced to DN 20, i.e. DN 20 pipework and accessories can be installed.

    16050 PVT

    10

    61

    11.4

    90

    145

    16.1

    7

    2

    1–15

    15

    16050 SST

    16

    56

    10.4

    90

    232

    14.8

    7

    2

    1–15

    20

    16090 PVT

    10

    109

    11.4

    160

    145

    28.8

    7

    2

    1–15

    15

    16090 SST

    16

    99

    10.3

    160

    232

    26.2

    7

    2

    1–15

    20

    16130 PVT

    10

    131

    10.9

    200

    145

    34.6

    7

    2

    1–15

    15

    16130 SST

    16

    129

    10.9

    200

    232

    34.1

    7

    2

    1–15

    20

    07120 PVT

    7

    150

    27.4

    90

    102

    39.6

    5

    1

    1 1/2–25 *

    16

    07120 SST

    7

    150

    27.4

    90

    102

    39.6

    5

    1

    1 1/2–25

    24

    07220 PVT

    7

    271

    27.7

    160

    102

    71.6

    5

    1

    1 1/2–25

    16

    07220 SST

    7

    271

    27.7

    160

    102

    71.6

    5

    1

    1 1/2–25

    24

    04350 PVT

    4

    353

    29.4

    200

    58

    93.3

    5

    1

    1 1/2–25

    16

    04350 SST

    4

    353

    29.4

    200

    58

    93.3

    5

    1

    1 1/2–25

    24

    Materials in Contact With the Medium

    Identity code of material

    Dosing head

    Suction/discharge connection

    Seals/ball seat

    Balls

    Integral relief valve

    * With 07120, 07220, 04350

    PVT

    PVDF

    PVDF

    PTFE/PTFE

    Ceramic/glass *

    PVDF/FKM or EPDM

    SST

    Stainless steel 1.4404

    Stainless steel 1.4581

    PTFE/PTFE

    Stainless steel 1.4404

    Stainless steel/FKM or EPDM

    Sealing material “F“ - "FDA" ball seat version: PVDF

    Sealing material “G” - (EC) Regulation 1935/2004" ball seat version: 1.4404

    Motor Data

    Identity code specification Power supply  Remarks
    U1-phase, IP 65100 – 230 V ±10 % / 240 V ±6 %50/60 Hz220 W 

    Motors less than 0.75 kW and motors designed for speed-controllable operation are not subject to the IE3 standard in compliance with the Ecodesign Directive 2009/125/EC.

    Downloads for Motor-Driven Metering Pump Sigma X Control Type – Sigma/ 2 - S2Cb

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by A to Z
    Load more matches ...
    No more matches available!

    Unfortunately, we did not find an appropriate match.

    All words written correctly?
    Search again with fewer or different search terms?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    The new Sigma X family – reliable, smart and with scope for networking

    The Sigma X diaphragm metering pump covers a capacity range of 21 to 1,040 l/h in versions S1Cb, S2Cb and S3Cb. Its patented multi-layer safety diaphragm guarantees maximum process reliability. Efficient protection of the power end from overloading by means of an integral frequency converter with microprocessor control(ler).

    One highlight is the standardised operating concept with click wheel and 4 additional operating keys on a removable operating unit. A large illuminated LCD and a 3-LED display for operating, warning and error messages, visible from all sides, offers additional operating convenience.

    The Sigma, like all smart ProMinent metering pumps, can be flexibly connected to various bus systems.

    It has a large adjustment range thanks to a combination of frequency and stroke length adjustment. The pump works with high precision across the entire frequency range. Accurate and complication-free metering of viscous and gaseous media by adjustment of the movement profile.

    Operating statuses are simply remotely transmitted via an additional output or relay module. A built-in timer, included as standard, controls time-dependent metering cycles.

    Relevant spare parts can be shown in the display. The integral log book significantly improves process management, optimisation and troubleshooting.

    Your benefits

    • Safe: In the event of an accident, the feed chemical does not escape to the outside nor into the pump's power end, thanks to the patented multi-layer safety diaphragm with optical (optionally electric) signalling.
    • Integrated overload shut-down in the pump control to protect the pump from overloading and thus significantly reduce pressure surges caused by blockages.
    • External control is scalable via potential-free contacts with pulse step-up and step-down, batch mode or via a 0/4-20 mA standard signal.
    • Flexibly connectible: Connection to process management systems via integral PROFIBUS®, CANopen interface.
    • Integral log book saves up to 300 events and simplifies troubleshooting and analysis of the cause.

    Video

    Application

    Technical Data

    Downloads

    Contact us

    Wesley Sutton

    Managing Director, ProMinent Fluid Controls UK Ltd.

    »We are always available to help. Don't hesitate to contact us.«

    +44 1530 560 555  Send request   

    Spare Parts and Accessories

    1 2 3

    Matching Products

    1 2 3 4

    ProMinent Newsletter - receive latest news, customized for you! subscribe now