Motor-Driven Metering Pump Sigma X Control Type – Sigma/ 2 - S2Cb
Capacity range S2Cb: 61 – 353 l/h, 16 – 4 bar
The Sigma control type is a smart motor-driven metering pump that is setting new standards in terms of productivity, reliability and safety.
Product description
The new Sigma X family – reliable, smart and with scope for networking
The Sigma X diaphragm metering pump covers a capacity range of 21 to 1,040 l/h in versions S1Cb, S2Cb and S3Cb. Its patented multi-layer safety diaphragm guarantees maximum process reliability. Efficient protection of the power end from overloading by means of an integral frequency converter with microprocessor control(ler).
One highlight is the standardised operating concept with click wheel and 4 additional operating keys on a removable operating unit. A large illuminated LCD and a 3-LED display for operating, warning and error messages, visible from all sides, offers additional operating convenience.
The Sigma, like all smart ProMinent metering pumps, can be flexibly connected to various bus systems.
It has a large adjustment range thanks to a combination of frequency and stroke length adjustment. The pump works with high precision across the entire frequency range. Accurate and complication-free metering of viscous and gaseous media by adjustment of the movement profile.
Operating statuses are simply remotely transmitted via an additional output or relay module. A built-in timer, included as standard, controls time-dependent metering cycles.
Relevant spare parts can be shown in the display. The integral logbook significantly improves process management, optimisation and troubleshooting.
Your benefits
- Safe: In the event of an accident, the feed chemical does not escape to the outside nor into the pump's power end, thanks to the patented multi-layer safety diaphragm with optical signalling (electrical as an option).
- Integrated overload shut-down in the pump control to protect the pump from overloading and thus significantly reduce pressure surges caused by blockages.
- External control is scalable via potential-free contacts with pulse step-up and step-down, batch mode or via a 0/4-20 mA standard signal.
- Can be flexibly networked: Connection to process management systems via integral PROFIBUS®.
- Integral log book saves up to 300 events and simplifies troubleshooting and analysis of the cause.
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- All industrial applications, either as a stand-alone unit or integrated in a complete system
- Volume-proportional addition of chemicals in water treatment, e.g. sodium hypochlorite for the disinfection of potable water
- Neutralisation in wastewater treatment
- Pulse-controlled metering in the bottling of different volumes e.g. glycerol filling of manometers
- With an integrated timer as a control unit for simple processes, e.g. biocide metering in cooling water
Technical Details
- Stroke length: 5 mm
- Stroke length adjustment range: 0 – 100%
- Stroke length adjustment: manually using self-locking rotary dial in 1 % increments
- With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
- Power supply: 1-phase, 100 – 230 V ±10%, 240 V ±6%, 50/60 Hz (220 W)
- Degree of protection IP 65
- Fibreglass-reinforced plastic housing
- Manual or external contact mode can be set, factor with external contact control 99:1 – 1:99; batch mode with max. 99,999 strokes/start pulse.
- Display of wear parts in the Service menu.
- Connector for 2-stage level switch.
- Connection to PROFINET using the ProMinent DULCOnvert PROFIBUS®-PROFINET converter.
- Variants with EU 1935/2004, FDA or hygienic design can be selected for food and other applications. Hygienic design liquid ends are available for applications with stringent hygiene requirements.
- Various relay modules can be selected.
- Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
- Customised designs are available on request.
For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps.
Technical Data
Type | Capacity at max. back pressure | Max. stroke rate | Pump capacity at max. back pressure | Suction lift | Perm. pre-pressure suction side | Connector Suction/Discharge Side | Shipping weight | |||
---|---|---|---|---|---|---|---|---|---|---|
S2Cb | l/h | bar | ml/stroke | Strokes/min | gph (US) | psi | m WC | bar | G-DN | kg |
* For the Sigma types 07120, 07220 and 04350, the dosing head is fitted with DN 25 (G 1 1/2) valves. As DN 20 is generally sufficient for the pipework for these types (see technical data, suction/discharge side connector), the connector parts that can be ordered with the identity code (e.g. inserts) are already reduced to DN 20, i.e. DN 20 pipework and accessories can be installed. | ||||||||||
16050 PVT | 61 | 10 | 11.4 | 90 | 16.1 | 145 | 7 | 2 | 1–15 | 15 |
16050 SST | 56 | 16 | 10.4 | 90 | 14.8 | 232 | 7 | 2 | 1–15 | 20 |
16090 PVT | 109 | 10 | 11.4 | 160 | 28.8 | 145 | 7 | 2 | 1–15 | 15 |
16090 SST | 99 | 16 | 10.3 | 160 | 26.2 | 232 | 7 | 2 | 1–15 | 20 |
16130 PVT | 131 | 10 | 10.9 | 200 | 34.6 | 145 | 7 | 2 | 1–15 | 15 |
16130 SST | 129 | 16 | 10.9 | 200 | 34.1 | 232 | 7 | 2 | 1–15 | 20 |
07120 PVT * | 150 | 7 | 27.4 | 90 | 39.6 | 102 | 5 | 1 | 1 1/2–25 | 16 |
07120 SST * | 150 | 7 | 27.4 | 90 | 39.6 | 102 | 5 | 1 | 1 1/2–25 | 24 |
07220 PVT * | 271 | 7 | 27.7 | 160 | 71.6 | 102 | 5 | 1 | 1 1/2–25 | 16 |
07220 SST * | 271 | 7 | 27.7 | 160 | 71.6 | 102 | 5 | 1 | 1 1/2–25 | 24 |
04350 PVT * | 353 | 4 | 29.4 | 200 | 93.3 | 58 | 5 | 1 | 1 1/2–25 | 16 |
04350 SST * | 353 | 4 | 29.4 | 200 | 93.3 | 58 | 5 | 1 | 1 1/2–25 | 24 |
Integrated relief valve, connector for DN 10 pressure hose sleeve
Materials in Contact with the Medium
Identity code of material | Dosing head | Connection on suction/discharge side | Seals/ball seat | Balls | Integral relief valve |
---|---|---|---|---|---|
* With 07120, 07220, 04350 | |||||
PVT | PVDF | PVDF | PTFE/PTFE | Ceramic/glass * | PVDF/FKM or EPDM |
SST | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/PTFE | Stainless steel 1.4404 | Stainless steel/FKM or EPDM |
PVF | PVDF | PVDF | PTFE/PTFE | Ceramic/glass * | PVDF/FKM or EPDM |
SSF | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/PTFE | Stainless steel 1.4404 | Stainless steel/FKM or EPDM |
SSG | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/stainless steel 1.4404 | Stainless steel 1.4404 | - |
SSH | Stainless steel 1.4435 | Stainless steel 1.4435 | EPDM or FKM/stainless steel 1.4435 | Ceramic | - |
Motor Data
Identity code specification | Power supply | Remarks | |||
U | 1-phase, IP 65 | 100 – 230 V ±10 % / 240 V ±6 % | 50/60 Hz | 220 W | Wide-range voltage power unit |
Motors less than 0.75 kW and motors designed for speed-controllable operation are not subject to the IE3 standard in compliance with the Ecodesign Directive 2009/125/EC.
Downloads for Motor-Driven Metering Pump Sigma X Control Type – Sigma/ 2 - S2Cb
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
The new Sigma X family – reliable, smart and with scope for networking
The Sigma X diaphragm metering pump covers a capacity range of 21 to 1,040 l/h in versions S1Cb, S2Cb and S3Cb. Its patented multi-layer safety diaphragm guarantees maximum process reliability. Efficient protection of the power end from overloading by means of an integral frequency converter with microprocessor control(ler).
One highlight is the standardised operating concept with click wheel and 4 additional operating keys on a removable operating unit. A large illuminated LCD and a 3-LED display for operating, warning and error messages, visible from all sides, offers additional operating convenience.
The Sigma, like all smart ProMinent metering pumps, can be flexibly connected to various bus systems.
It has a large adjustment range thanks to a combination of frequency and stroke length adjustment. The pump works with high precision across the entire frequency range. Accurate and complication-free metering of viscous and gaseous media by adjustment of the movement profile.
Operating statuses are simply remotely transmitted via an additional output or relay module. A built-in timer, included as standard, controls time-dependent metering cycles.
Relevant spare parts can be shown in the display. The integral logbook significantly improves process management, optimisation and troubleshooting.
Your benefits
- Safe: In the event of an accident, the feed chemical does not escape to the outside nor into the pump's power end, thanks to the patented multi-layer safety diaphragm with optical signalling (electrical as an option).
- Integrated overload shut-down in the pump control to protect the pump from overloading and thus significantly reduce pressure surges caused by blockages.
- External control is scalable via potential-free contacts with pulse step-up and step-down, batch mode or via a 0/4-20 mA standard signal.
- Can be flexibly networked: Connection to process management systems via integral PROFIBUS®.
- Integral log book saves up to 300 events and simplifies troubleshooting and analysis of the cause.
Video
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- All industrial applications, either as a stand-alone unit or integrated in a complete system
- Volume-proportional addition of chemicals in water treatment, e.g. sodium hypochlorite for the disinfection of potable water
- Neutralisation in wastewater treatment
- Pulse-controlled metering in the bottling of different volumes e.g. glycerol filling of manometers
- With an integrated timer as a control unit for simple processes, e.g. biocide metering in cooling water
Technical Data
Technical Details
- Stroke length: 5 mm
- Stroke length adjustment range: 0 – 100%
- Stroke length adjustment: manually using self-locking rotary dial in 1 % increments
- With the right, constant conditions, correct installation and calibration, precision exceeds ±1 %, based on maximum stroke volume.
- Power supply: 1-phase, 100 – 230 V ±10%, 240 V ±6%, 50/60 Hz (220 W)
- Degree of protection IP 65
- Fibreglass-reinforced plastic housing
- Manual or external contact mode can be set, factor with external contact control 99:1 – 1:99; batch mode with max. 99,999 strokes/start pulse.
- Display of wear parts in the Service menu.
- Connector for 2-stage level switch.
- Connection to PROFINET using the ProMinent DULCOnvert PROFIBUS®-PROFINET converter.
- Variants with EU 1935/2004, FDA or hygienic design can be selected for food and other applications. Hygienic design liquid ends are available for applications with stringent hygiene requirements.
- Various relay modules can be selected.
- Wetted materials: PVDF, stainless steel 1.4571/1.4404, special materials on request
- Customised designs are available on request.
For reasons of safety, provide suitable overflow devices during installation for all mechanically deflected diaphragm metering pumps.
Technical Data
Type | Capacity at max. back pressure | Max. stroke rate | Pump capacity at max. back pressure | Suction lift | Perm. pre-pressure suction side | Connector Suction/Discharge Side | Shipping weight | |||
---|---|---|---|---|---|---|---|---|---|---|
S2Cb | l/h | bar | ml/stroke | Strokes/min | gph (US) | psi | m WC | bar | G-DN | kg |
* For the Sigma types 07120, 07220 and 04350, the dosing head is fitted with DN 25 (G 1 1/2) valves. As DN 20 is generally sufficient for the pipework for these types (see technical data, suction/discharge side connector), the connector parts that can be ordered with the identity code (e.g. inserts) are already reduced to DN 20, i.e. DN 20 pipework and accessories can be installed. | ||||||||||
16050 PVT | 61 | 10 | 11.4 | 90 | 16.1 | 145 | 7 | 2 | 1–15 | 15 |
16050 SST | 56 | 16 | 10.4 | 90 | 14.8 | 232 | 7 | 2 | 1–15 | 20 |
16090 PVT | 109 | 10 | 11.4 | 160 | 28.8 | 145 | 7 | 2 | 1–15 | 15 |
16090 SST | 99 | 16 | 10.3 | 160 | 26.2 | 232 | 7 | 2 | 1–15 | 20 |
16130 PVT | 131 | 10 | 10.9 | 200 | 34.6 | 145 | 7 | 2 | 1–15 | 15 |
16130 SST | 129 | 16 | 10.9 | 200 | 34.1 | 232 | 7 | 2 | 1–15 | 20 |
07120 PVT * | 150 | 7 | 27.4 | 90 | 39.6 | 102 | 5 | 1 | 1 1/2–25 | 16 |
07120 SST * | 150 | 7 | 27.4 | 90 | 39.6 | 102 | 5 | 1 | 1 1/2–25 | 24 |
07220 PVT * | 271 | 7 | 27.7 | 160 | 71.6 | 102 | 5 | 1 | 1 1/2–25 | 16 |
07220 SST * | 271 | 7 | 27.7 | 160 | 71.6 | 102 | 5 | 1 | 1 1/2–25 | 24 |
04350 PVT * | 353 | 4 | 29.4 | 200 | 93.3 | 58 | 5 | 1 | 1 1/2–25 | 16 |
04350 SST * | 353 | 4 | 29.4 | 200 | 93.3 | 58 | 5 | 1 | 1 1/2–25 | 24 |
Integrated relief valve, connector for DN 10 pressure hose sleeve
Materials in Contact with the Medium
Identity code of material | Dosing head | Connection on suction/discharge side | Seals/ball seat | Balls | Integral relief valve |
---|---|---|---|---|---|
* With 07120, 07220, 04350 | |||||
PVT | PVDF | PVDF | PTFE/PTFE | Ceramic/glass * | PVDF/FKM or EPDM |
SST | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/PTFE | Stainless steel 1.4404 | Stainless steel/FKM or EPDM |
PVF | PVDF | PVDF | PTFE/PTFE | Ceramic/glass * | PVDF/FKM or EPDM |
SSF | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/PTFE | Stainless steel 1.4404 | Stainless steel/FKM or EPDM |
SSG | Stainless steel 1.4404 | Stainless steel 1.4581 | PTFE/stainless steel 1.4404 | Stainless steel 1.4404 | - |
SSH | Stainless steel 1.4435 | Stainless steel 1.4435 | EPDM or FKM/stainless steel 1.4435 | Ceramic | - |
Motor Data
Identity code specification | Power supply | Remarks | |||
U | 1-phase, IP 65 | 100 – 230 V ±10 % / 240 V ±6 % | 50/60 Hz | 220 W | Wide-range voltage power unit |
Motors less than 0.75 kW and motors designed for speed-controllable operation are not subject to the IE3 standard in compliance with the Ecodesign Directive 2009/125/EC.
Downloads
Downloads for Motor-Driven Metering Pump Sigma X Control Type – Sigma/ 2 - S2Cb
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.