Suggestions

Back pressure valves/relief valves for Diaphragm Metering Pumps

Back pressure valves are used to generate a constant back pressure and achieve precise metering in systems with a free outlet. They are also used in conjunction with pulsation dampers to provide low-pulsation metering.

Product description

Accurately metered

Back pressure valves for Diaphragm Metering Pumps are designed for various applications. Please refer to the relevant instructions for the different construction types.

Relief valves are installed in the bypass to protect pumps, pipes, and fittings from excessive pressure in the event of operator error or clogging. In the event of a malfunction, the pump returns the fluid to the supply tank.

The benefits for you

  • Protects against overpressure
  • Priming aid
  • Relieves the pressure line
  • Increases dosing precision

Back Pressure Valve/Relief Valve Type DHV-U

The universally applicable back pressure valves of the DHV-U product range are internally flowed, piston diaphragm valves with no back pressure effect. They are used to generate a constant back pressure and as a relief valve. They can be installed at any point in the piping system.

Adjustable pressure    0.5 - 10 bar

Application of PPE/PPB/PCE/PCB

20 °C - max. operating pressure 10 bar

Application of PVT/PVE/SST

30 °C - max. operating pressure 10 bar

Version

Nominal diameter

Dim. G

Order no.

PVT

DN 10

3/4

1139731

PVE

DN 10

3/4

1139847

PCB Version

DN 10

3/4

1139727

PCE

DN 10

3/4

1139729

SST

DN 10

3/4

1043194

PVT

DN 15

1

1139732

PVE

DN 15

1

1139848

PCB

DN 15

1

1139728

PCE

DN 15

1

1139730

SST

DN 15

1

1043193

PVT

DN 20

1 1/4

1037777

PPE

DN 20

1 1/4

1037284

PCB

DN 20

1 1/4

1037775

PPB

DN 20

1 1/4

1038147

PCE

DN 20

1 1/4

1038148

SST

DN 20

1 1/4

1043192

PCE

DN 25

1 1/2

1038150

PPE

DN 25

1 1/2

1036633

PCB

DN 25

1 1/2

1037774

PVT

DN 25

1 1/2

1037776

PPB

DN 25

1 1/2

1038149

SST

DN 25

1 1/2

1043191

PPE

DN 32

2

1051517

PVT

DN 32

2

1051503

PCE

DN 32

2

1051514

SST

DN 32

2

1051516

PCB

DN 32

2

1051520

PPB

DN 32

2

1051522

PPE

DN 40

2 1/4

1051518

PCE

DN 40

2 1/4

1051501

PVT

DN 40

2 1/4

1051502

SST

DN 40

2 1/4

1051515

PCB

DN 40

2 1/4

1051519

PPB

DN 40

2 1/4

1051521

Materials used

Version

Housing/Connectors

Plungers

Plunger Seal

Seal/Connectors

* Cover ring made from PTFE/FKM

PPE

PP

PVDF

EPDM

EPDM

PPB

PP

PVDF

FKM

FKM

PCE

PVC

PVDF

EPDM

EPDM

PCB

PVC

PVDF

FKM

FKM

PVT

PVDF

PVDF

PTFE *

FKM

SST

1.4404

PTFE

PTFE *

PTFE

Dimensions of DHV-U (PP, PVC, PVDF design)

DN

G

H

L

h

D

m

B

mm

mm

mm

mm

mm

10

3/4

144

118

24

79

M6

40

15

1

144

118

24

79

M6

40

20

1 1/4

196

150

37

99

M6

46

25

1 1/2

196

150

37

99

M6

46

32

2

252

200

54

139.5

M8

65

40

2 1/4

252

200

54

139.5

M8

65

Dimensions of DHV-U (SS version)

DN

G

H*

L

h

D

m

B

mm

mm

mm

mm

mm

* Approximate values

10

3/4

144

118

20

79

M6

40

15

1

144

118

20

79

M6

40

20

1 1/4

196

150

30

99

M6

46

25

1 1/2

196

150

30

99

M6

46

32

2

252

200

37

139.5

M8

65

40

2 1/4

252

200

37

139.5

M8

65

  • p_ac_0256_m
  • p_moz_0005_sw

Back Pressure Valve/Relief Valve Type DHV-U in physiologically safe design (FDA)

Back pressure valves for Diaphragm Metering Pumps are designed for various applications. Please refer to the relevant instructions for the different construction types.

Relief valves are installed in the bypass to protect pumps, pipes, and fittings from excessive pressure in the event of operator error or clogging. In the event of a malfunction, the pump returns the fluid to the supply tank.

Adjustable pressure    0.5 - 10 bar

Application of PPE/PPB/PCE/PCB

20 °C - max. operating pressure 10 bar

Application of PVT/PVE/SST

30 °C - max. operating pressure 10 bar

Version

Nominal diameter

Dim. G

Order no.

PVE

DN 10

3/4

1139847

SST

DN 10

3/4

1076532

PVT

DN 10

3/4

1139733

PPE

DN 15

1

1139848

SST

DN 15

1

1076531

PVT

DN 15

1

1139734

PVT

DN 20

1 1/4

1076583

PPE

DN 20

1 1/4

1076582

SST

DN 20

1 1/4

1076597

PPE

DN 25

1 1/2

1076585

SST

DN 25

1 1/2

1076584

PVT

DN 25

1 1/2

1076586

PVT

DN 32

2

1076588

PPE

DN 32

2

1076587

SST

DN 32

2

1076589

PPE

DN 40

2 1/4

1076590

PVT

DN 40

2 1/4

1076591

SST

DN 40

2 1/4

1076592

Materials used

Version

Housing/Connectors

Plungers

Plunger Seal

Seal/Connectors

* Cover ring made from PTFE/FKM

PVE

PP

PVDF

EPDM

EPDM

PVT

PVDF

PVDF

PTFE *

FKM

SST

1.4404

PTFE

PTFE *

PTFE

All wetted materials in the 'Physiologically safe (FDA) in respect of wetted materials' design comply with the following FDA guidelines:

MaterialGuideline
PTFE21CFR177.1510
PVDF21CFR177.2510
PP21CFR177.1520
EPDM/FKM21CFR177.2600

We are happy to supply back pressure valves and relief valves DHV-U/DHV-UR in stainless steel and wetted EC 1935/2004 on request.

  • p_ac_0256_m
  • p_moz_0005_sw

Relief valve type DHV-UR

The universal relief valves type DHV-UR, like all valves of the DHV-U product range, are infinitely adjustable piston diaphragm valves with internal flow. In the event of impermissible overpressure, the internal piston diaphragm opens the second outlet line, the relief outlet. It can be installed at any location in the pipework system. Very low pressure losses with a closed relief valve due to virtually free pipe cross-section Simple spare parts management, the wear parts (pressure spring, diaphragms, plunger seal, seal connection set) correspond to the DHV-U range of valves.

The benefits of the new relief valves DHV-UR include simpler assembly due to the saving of installation material/connection parts etc. and a reduction of adhesion points. The new installation method permits a slimmer design of metering stations.

Relief valves for direct installation in the pressure line of the Diaphragm Metering Pump, with the following functions:

  • Installation at any point in the piping system
  • Very low pressure losses when the relief valve is closed due to a virtually unobstructed pipe cross-section

Adjustable pressure

0.5 – 10 bar

Application: PP and PVC (PPE/PPB/PCE/PCB)

20 °C – maximum operating pressure 10 bar

Application for PVDF and stainless steel (PVT/SST)

30 °C – maximum operating pressure 10 bar

Your benefits:

  • Simpler installation due to reduced need for mounting hardware and fittings
  • Fewer bonding points.
  • More compact construction type of metering stations.
  • Simple spare parts management; wear parts are compatible with the DHV-U valve series.

Version

Nominal diameter

Dim. G

Order no.

PVT

DN 10

3/4

1061365

PPE

DN 10

3/4

1061337

PCE

DN 10

3/4

1061339

PPB

DN 10

3/4

1061341

PCB

DN 10

3/4

1061343

SST

DN 10

3/4

1061550

PCB

DN 15

1

1061342

PPE

DN 15

1

1061336

PCE

DN 15

1

1061338

PPB

DN 15

1

1061340

PVT

DN 15

1

1061364

SST

DN 15

1

1061551

PCE

DN 20

1 1/4

1061369

PPE

DN 20

1 1/4

1061367

PPB

DN 20

1 1/4

1061371

PCB

DN 20

1 1/4

1061373

PVT

DN 20

1 1/4

1061375

SST

DN 20

1 1/4

1061569

PCE

DN 25

1 1/2

1061368

PPE

DN 25

1 1/2

1061366

PPB

DN 25

1 1/2

1061370

PCB

DN 25

1 1/2

1061372

PVT

DN 25

1 1/2

1061374

SST

DN 25

1 1/2

1061570

Materials used

Version

Housing/Connectors

Plungers

Plunger Seal

Seal/Connectors

* Cover ring made from PTFE/FKM

PPE

PP

PVDF

EPDM

EPDM

PPB

PP

PVDF

FKM

FKM

PCE

PVC

PVDF

EPDM

EPDM

PCB

PVC

PVDF

FKM

FKM

PVT

PVDF

PVDF

PTFE *

FKM

SST

1.4404

1.4404

PTFE *

PTFE

Dimensions of DHV-UR (PP, PVC, PVDF design)

DN

G

H*

L

h

D

m

B

mm

mm

mm

mm

mm

* Approximate values

10

3/4

144

118

24

79

M6

35

15

1

144

118

24

79

M6

35

20

1 1/4

196

150

37

99

M6

46

25

1 1/2

196

150

37

99

M6

46

Dimensions of DHV-UR (SS design)

DN

G

H*

L

h

D

m

B

mm

mm

mm

mm

mm

* Approximate values

10

3/4

144

118

24

79

M6

35

15

1

144

118

24

79

M6

35

20

1 1/4

196

150

37

99

M6

46

25

1 1/2

196

150

37

99

M6

46

  • p_ac_0267_v2
  • p_ac_0268_v2

Relief valve type DHV-UR, FDA design

Back pressure valves for Diaphragm Metering Pumps are designed for various applications. Please refer to the relevant instructions for the different construction types.

Relief valves are installed in the bypass to protect pumps, pipes, and fittings from excessive pressure in the event of operator error or clogging. In the event of a malfunction, the pump returns the fluid to the supply tank.

Adjustable pressure    0.5 - 10 bar

Application of PPE/PPB/PCE/PCB:

20 °C - max. operating pressure 10 bar

Application of PVT/SST:

30 °C - max. operating pressure 10 bar

Version

Nominal diameter

Dim. G

Order no.

PVT

DN 10

3/4

1075830

PPE

DN 10

3/4

1075828

SST

DN 10

3/4

1075847

PVT

DN 15

1

1075829

PPE

DN 15

1

1075827

SST

DN 15

1

1075846

PPE

DN 20

1 1/4

1075833

PVT

DN 20

1 1/4

1075845

SST

DN 20

1 1/4

1075849

PVT

DN 25

1 1/2

1075844

PPE

DN 25

1 1/2

1075832

SST

DN 25

1 1/2

1075848

Materials used

Version

Housing/Connectors

Plungers

Plunger Seal

Seal/Connectors

* Cover ring made from PTFE/FKM

PPE

PP

PVDF

EPDM

EPDM

PVT

PVDF

PVDF

PTFE *

FKM

SST

1.4404

PTFE

PTFE *

PTFE

All wetted materials in the 'Physiologically safe (FDA) in respect of wetted materials' design comply with the following FDA guidelines:

MaterialGuideline
PTFE21CFR177.1510
PVDF21CFR177.2510
PP21CFR177.1520
EPDM/FKM21CFR177.2600

Dimensions of DHV-UR (FDA) (PP, PVC, PVDF design)

DN

G

H*

L

h

D

m

B

mm

mm

mm

mm

mm

* Approximate values

10

3/4

144

118

24

79

M6

35

15

1

144

118

24

79

M6

35

20

1 1/4

196

150

37

99

M6

46

25

1 1/2

196

150

37

99

M6

46

Dimensions of DHV-UR (FDA) (SS design)

DN

G

H*

L

h

D

m

B

mm

mm

mm

mm

mm

* Approximate values

10

3/4

144

118

24

79

M6

35

15

1

144

118

24

79

M6

35

20

1 1/4

196

150

37

99

M6

46

25

1 1/2

196

150

37

99

M6

46

We are happy to supply back pressure valves and relief valves DHV-U/DHV-UR in stainless steel and wetted EC 1935/2004 on request.

  • p_ac_0267_v2
  • p_ac_0268_v2

Relief valve type DHV-UR M configured for manometer

The relief valves DHV-UR with M designs are configured with a plug for manometer installation. Manometer with threaded socket G 1/4“ (ISO 228) can be fitted by the customer directly to the relief valve via the additional housing opening. Standard manometers with part number are available for neutral media. This also enables savings in terms of installation.

Adjustable pressure    0.5 - 10 bar

Application of PPE/PPB/PCE/PCB

20 °C - max. operating pressure 10 bar

Application of PVT/SST

30 °C - max. operating pressure 10 bar

Version

Nominal diameter

Dim. G

Order no.

PPE

DN 10

3/4

1077221

PPB

DN 10

3/4

1077259

PCE

DN 10

3/4

1077255

PVT

DN 10

3/4

1077267

PCB

DN 10

3/4

1077263

PPE

DN 15

1

1077220

PPB

DN 15

1

1077258

PCE

DN 15

1

1077254

PCB

DN 15

1

1077262

PVT

DN 15

1

1077266

PPE

DN 20

1 1/4

1077219

PCE

DN 20

1 1/4

1077223

PCB

DN 20

1 1/4

1077261

PVT

DN 20

1 1/4

1077265

PPB

DN 20

1 1/4

1077257

PPE

DN 25

1 1/2

1077218

PPB

DN 25

1 1/2

1077256

PCE

DN 25

1 1/2

1077222

PCB

DN 25

1 1/2

1077260

PVT

DN 25

1 1/2

1077264

Materials used

Version

Housing/Connectors

Plungers

Plunger Seal

Seal/Connectors

* Cover ring made from PTFE/FKM

PPE

PP

PVDF

EPDM

EPDM

PPB

PP

PVDF

FKM

FKM

PCE

PVC

PVDF

EPDM

EPDM

PVT

PVDF

PVDF

PTFE *

FKM

PCB

PVC

PVDF

FKM

FKM

Dimensions of DHV-UR M (PP, PVC, PVDF design)

DN

G

H*

L

h

D

m

B

mm

mm

mm

mm

mm

* Approximate values

10

3/4

144

118

24

79

M6

35

15

1

144

118

24

79

M6

35

20

1 1/4

196

150

37

99

M6

46

25

1 1/2

196

150

37

99

M6

46

  • p_ac_0267_v2

Back Pressure Valve / Relief Valve Type DHV 712-R

Adjustable pressure    0.5 - 10 bar

Application of PPE/PCB

20 °C - max. operating pressure 10 bar

Application of PVT/TT/SS

30 °C - max. operating pressure 10 bar

Version

Nominal diameter

Dim. G

Order no.

TT

DN 10

3/4

1000059

TT

DN 15

1

1000060

TT

DN 20

1 1/4

1000061

TT

DN 25

1 1/2

1000062

TT

DN 32

2

1000063

TT

DN 40

2 1/4

1000064

Caution: The product contains adhesive joints with Tangit. Please note the resistance of Tangit adhesive.

Dimensions of DHV 712-R

Dimension DN

Dim. G

Dim. H

Dim. L

Dimension h

Dim. D

Dimension m

DN

G

H

L

h

D

m

10

3/4

173

120

-

81

M6

15

1

173

120

-

81

M6

20

1 1/4

201

150

-

107

M6

25

1 1/2

201

150

-

107

M6

32

2

260

205

59 / 37

147

M8

40

2 1/4

260

205

59 / 37

147

M8

Materials used

Version

Housing/Connectors

Plungers

Plunger Seal

Seal/Connectors

TT

Carbon-filled PTFE

PTFE

PTFE

PTFE

  • pk_2_031

Back Pressure Valve / Relief Valve for High-Pressure Systems

Material: stainless steel 316/FKM

Temperature range: -18 °C to 120 °C

Recommended use up to 200 l/h

Connector size

Order no.

Overflow valve

1/4" NPT inner and outer thread

202505

Spring counter pressure min.

Spring counter pressure max.

Spring colour

Order no.

bar

bar

3.4

24

blue

202519

24.0

52

yellow

202520

52.0

103

violet

202525

103.0

155

orange

202524

155.0

207

brown

202523

207.0

276

white

202522

276.0

345

red

202521

Recommended use up to 300 l/h

Connector size

Order no.

Overflow valve

1/2" NPT inner and outer thread

1005499

Spring counter pressure min.

Spring counter pressure max.

Spring colour

Order no.

bar

bar

3.4

24

blue

1005500

24.0

50

yellow

1005501

50.0

100

violet

1005502

Reducing pipe nipple

Connector size

Order no.

1/4" NPT internal – 1/4" NPT external (A)

359378

1/4" NPT external – 1/4 Rp internal (B)

359379

1/2" NPT internal – 1/2" NPT external (A)

1005503

1/2" NPT external – 1/2 Rp internal (B)

1005504

For use as an adjustable safety relief valve and as a back pressure valve. Relief valve and corresponding spring must be ordered separately

  • pk_2_032

Downloads for Back pressure valves/relief valves for Diaphragm Metering Pumps

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

Accurately metered

Back pressure valves for Diaphragm Metering Pumps are designed for various applications. Please refer to the relevant instructions for the different construction types.

Relief valves are installed in the bypass to protect pumps, pipes, and fittings from excessive pressure in the event of operator error or clogging. In the event of a malfunction, the pump returns the fluid to the supply tank.

The benefits for you

  • Protects against overpressure
  • Priming aid
  • Relieves the pressure line
  • Increases dosing precision

Technical Data

Downloads

Contact us

Wesley Sutton

Managing Director, ProMinent Fluid Controls UK Ltd.

»We are always available to help. Don't hesitate to contact us.«

+44 1530 560 555  Send request   

Matching Products

The sigma S1Ba is a highly robust Diaphragm Metering Pump featuring a patented multi-layer safety diaphragm for high process reliability. It offers a wide range of drive options, such as three-phase or single-phase AC motors, including models for areas at risk from explosion.

more

Rugged Diaphragm Metering Pumps, such as the sigma S2Ba, ensure a high level of process reliability thanks to their patented multi-layer safety diaphragm. The Diaphragm Metering Pump offers a wide range of drive options, including those for areas at risk from explosion.

more

The patented multi-layer safety diaphragm, which ensures high process reliability, is just one feature of the highly robust sigma S3Ba Diaphragm Metering Pump. It also offers a wide range of drive options, such as three-phase or single-phase AC motors, including models for ATEX-compliant applications.

more

The sigma/X control type is an intelligent, flexible Diaphragm Metering Pump that sets new standards in terms of ease of use, reliability, and safety.

more

The sigma/X control type is an intelligent, flexible Diaphragm Metering Pump that sets new standards in terms of ease of use, reliability, and safety.

more

The sigma/X control type is an intelligent, flexible Diaphragm Metering Pump that sets new standards in terms of ease of use, reliability, and safety.

more

News and Events