Suggestions

Suction Lances, Suction Assemblies and Level Switches for Low-Pressure Metering Pumps

Suction lances, suction assemblies and level switches for a smooth metering process

Product description

The right kits for every metering task

The suction lance is installed at the lower end of the suction hose. It fixes the hose in the tank. This is particularly useful when there is a stirrer in the dosing tank. At the end of the suction lance is a foot valve with filter mesh. This protects the suction line from large particles and contaminants.

Suction assemblies are available with or without level monitoring.

The level switch signals the liquid level of the storage tank. In one-stage versions it transmits the signal when the tank is empty. In two-stage versions it also issues a warning before the tank is empty.

The benefits for you

  • Fixes the suction hose
  • Protects against large dirt particles and contamination
  • Signals the empty message of the supply tank
  • Signals the liquid level of the supply tank

Level Switch Kit Complete, PVDF, Two-Stage with Round Connector or Lead

The level switch set can be ordered in conjunction with the DN 10 - DN 32 suction assemblies.

For level monitoring in the supply tank, two-stage with pre-warning alarm message and switch-off of the metering pump after a further 30 mm reduction in level.

Switching mode when liquid level low: 2 x N/C

Technical data:

Max. switching voltage: 24 V

Switching current: 0.5 A

Switching power: 5 W/5 VA

Temperature range: -10 °C to 65 °C

Degree of protection: IP 67

Material:

Body of level switch PVDF, float PE, fastening lug PVDF, cable holder PE, anti-kink protection PE, cable PE.

Connector size

Version

Lead length

Order no.

m

DN10/15

with 3-pin round plug

3

1034879

DN 20

with 3-pin round plug

3

1034880

DN 25

with 3-pin round plug

3

1034881

DN 32

with 3-pin round plug

3

1034882

DN 10/15

with lead

5

1034883

DN 20

with lead

5

1034884

DN 25

with lead

5

1034885

DN 32

with lead

5

1034886

  • pk_2_035

Variable suction lance with two-stage level switch

Variable suction lance with two-stage level switch for connection to 5 - 60 litre disposable tanks, comprising a support pipe, foot valve, level switch with round connector, height-adjustable Ø 50 mm screw cap and 2 m suction line. Length 640 mm.

Switching mode when liquid level low: 2 x N/C

Suitable for metering pumps of the beta, gamma/ X, gamma/ XL and Dulcoflex DF4a (6 x 4) product ranges.

Note: For tank openings with Ø 44, the required screw cap Ø 44 is available as an individual part and can be swapped for the screw cap Ø 50 by the customer.

MaterialPPEPCB
Support pipe and foot valvePPPVC
Seals and valve ballEPDMFKM
HosePESoft PVC

Material

Length

Hose oØ x iØ

For tank

Order no.

mm

mm

PPE

640

6 x 4

5–60 l / 50 mm

802277

PPE

640

8 x 5

5–60 l / 50 mm

802278

PPE

640

12 x 9

5–60 l / 50 mm

790372

PCB

640

6 x 4

5–60 l / 50 mm

802077

PCB

640

8 x 5

5–60 l / 50 mm

802078

PCB

640

12 x 9

5–60 l / 50 mm

790371

  • pk_1_075

Screw Cap

For container openings with Ø 44, the required screw cap Ø 44 is available as an individual part and can be swapped for the screw cap Ø 50 by the customer.

Order no.

Ø 44 screw cap

811626

  • pk_1_066

Variable suction lance with two-stage level switch for 200-litre barrel

Variable suction lance with two-stage level switch for connection to 200 litre barrel, comprising a support pipe, foot valve, level switch with round connector, height-adjustable sealing stopper and 3 m suction line. Length 1,000 mm.

Switching mode when liquid level low: 2 x N/C

Suitable for metering pumps of the beta, gamma/ X and gamma/ XL product ranges.

Note: Adapters for other threads are available on request

MaterialPPEPCB
Support pipe and foot valvePPPVC
Seals and valve ballEPDMFKM
HosePESoft PVC

Material

Length

Hose oØ x iØ

For tank

Order no.

mm

mm

PPE

1,000

6 x 4

200 l

802279

PPE

1,000

8 x 5

200 l

802280

PPE

1,000

12 x 9

200 l

790374

PCB

1,000

6 x 4

200 l

802079

PCB

1,000

8 x 5

200 l

802080

PCB

1,000

12 x 9

200 l

790373

  • pk_1_076

Suction lance with two-stage level switch for 60-litre canister, fixed length, gas-tight

Variable suction lance with two-stage level switch for connection to 60 litre canister, gas-tight, comprising a support pipe, foot valve, level switch with round connector, Ø 55 mm screw cap and 2 m suction line. Length 560 mm. Design with vent valve and bleed valve.

Switching mode when liquid level low: 2 x N/C

Suitable for metering pumps of the beta, gamma/ X and gamma/ XL product ranges.

MaterialPPEPCB
Support pipe and foot valvePPPVC
Seals and valve ballEPDMFKM
HosePESoft PVC

Material

Length

Hose oØ x iØ

For tank

Order no.

mm

mm

PPE

560

6 x 4

60 l / 55 mm

802285

PPE

560

8 x 5

60 l / 55 mm

802286

PPE

560

12 x 9

60 l / 55 mm

802287

PCB

560

6 x 4

60 l / 55 mm

802081

PCB

560

8 x 5

60 l / 55 mm

802082

PCB

560

12 x 9

60 l / 55 mm

802083

  • p_ac_0052_sw

Suction lance with two-stage level switch

Fixed length suction lance made of PVDF with two-stage level switch, consisting of PVDF support pipe, foot valve, two-stage level switch with open end and PTFE suction line 8 x 6 mm.

Note: A matching connector kit for hose 8/6 to standard 6/4, 8/5 and 12/9 connectors is included in the scope of delivery.

Switch mode when liquid level low: 2 x N/C

Suitable for metering pumps of the beta, gamma/ X and gamma/ XL product ranges using a 2 m level sensor cable, order no. 707715.

MaterialPVT
Support pipe and foot valvePVDF
Seals and valve ballPTFE
HosePTFE

Material

Length

Hose oØ x iØ

For tank

Order no.

mm

mm

PVT

350

8 x 6

10–30 l

1038304

PVT

650

8 x 6

50–60 l

1038305

  • p_ac_0250_sw

Suction assembly with two-stage level switch for PE 35 dosing tanks up to 1,500 litres

Variable suction assembly with two-stage level switch for connection to 35 to 1,500 litre tanks, comprising a support pipe, foot valve, level switch with 3-pin round connector and 2 m suction line, or 3 m suction line for 1,000 litre tanks. Adjustable length.

For 1,500-litre tanks, fixed length with 3 m suction line.

Switching mode when liquid level low: 2 x N/C

Suitable for metering pumps of the beta, gamma/ X and gamma/ XL product ranges.

MaterialPPEPCB
Support pipe and foot valvePPPVC
Seals and valve ballEPDMFKM
HosePESoft PVC

Material

Long support pipe

Hose oØ x iØ

For tank

Order no.

mm

mm

PPE

375 – 550

6 x 4

35, 60 l

790365

PPE

375 – 550

8 x 5

35, 60 l

790366

PPE

375 – 550

12 x 9

35, 60 l

790367

PPE

655 – 1.060

6 x 4

100–500 l

790368

PPE

655 – 1.060

8 x 5

100–500 l

790369

PPE

655 – 1.060

12 x 9

100–500 l

790370

PPE

1.085 – 1.425

6 x 4

1000 l

790465

PPE

1.085 – 1.425

8 x 5

1000 l

790466

PPE

1.085 – 1.425

12 x 9

1000 l

790467

PPE

fixed length

6 x 4

1500 l

1077558

PPE

fixed length

8 x 5

1500 l

1077519

PPE

fixed length

12 x 9

1500 l

1077560

PCB

375 – 550

6 x 4

35, 60 l

790359

PCB

375 – 550

8 x 5

35, 60 l

790360

PCB

375 – 550

12 x 9

35, 60 l

790361

PCB

655 – 1.060

6 x 4

100–500 l

790362

PCB

655 – 1.060

8 x 5

100–500 l

790363

PCB

655 – 1.060

12 x 9

100–500 l

790364

PCB

1.085 – 1.425

6 x 4

1000 l

790462

PCB

1.085 – 1.425

8 x 5

1000 l

790463

PCB

1.085 – 1.425

12 x 9

1000 l

790464

PCB

fixed length

6 x 4

1500 l

1077559

PCB

fixed length

8 x 5

1500 l

1077520

PCB

fixed length

12 x 9

1500 l

1077561

  • pk_1_077

Two-Stage Float Switch

Two-stage level switch for level monitoring in the supply tank with pre-warning alarm message and for switching off the metering pump after a further 30 mm reduction in level.

With a 3-pin round connector for direct connection to metering pump or with 3 leads, e.g. in conjunction with relay control, order no. 914768.

Switching mode when liquid level low: 2 x N/C

Suitable for metering pumps of the beta, gamma/ X and gamma/ XL product ranges.

Technical data

Max. switching voltage: 24 V DC, Switching current: 0.5 A, Switching power: 5 W/5 VA,

Temperature range: - 10 °C to 65 °C, Degree of protection IP 67.

MaterialPVDF/PEPVDF/PVDF
Level switchPVDFPVDF
FloatPE foamedPVDF
CablePEPE

Material

Lead length

Order no.

m

PVDF/PE

Round plug

2

1031604

PVDF/PE

Round plug

5

1031606

PVDF/PE

Open end

2

1031607

PVDF/PE

Open end

5

1031609

PVDF/PVDF

Round plug

2

1034697

PVDF/PVDF

Round plug

5

1034698

PVDF/PVDF

Open end

2

1034699

PVDF/PVDF

Open end

5

1034700

Cable assignment on 3-wire cable:

ColourFunction
blackGround
blueMinimum pre-warning
brownMinimum limit stop

  • pk_1_081

Ceramic Weight for Vertical Fixing of Float Switch

Ø A

Dim. B

Ø C

Weight

Version

Order no.

mm

mm

mm

g

Size 1

25

50

10

60

For round and latch plug

1019244

Size 2

39

32

-

65

For round plug/flat connector

404004

Size 3

40

50

24

70

For round plug/flat connector

1030189

13 x 27 mm slot 

With the two-stage level switch with round connector, the weight is slid on from below after the float is removed.

  • pk_1_082

Level switch with support pipe

Level switch for use in media which attack the PE cable of the level switch and/or for stable attachment in conjunction with electric stirrer, FKM seal. Adjustable length.

2-stage switch mode when liquid level low: 2 x N/C

1-stage switch mode when liquid level low: 1 x N/O

MaterialPCB
Support pipePVC
SealsFKM
Level switchPVDF
CablePE

Material

Long support pipe

Float switch

Order no.

mm

PCB

350…550

two-stage with round connector

802010

PCB

660…1,160

two-stage with round connector

802011

PCB

350…550

single-stage with flat plug

801727

PCB

660…1,160

single-stage with flat plug

801728

  • pk_1_084

Extension Lead, 3-Core

Extension cable for level switch with 3-pin round plugs, comprising 3 m cable, plug and coupling.

Order no.

Extension cable, 3-pin, 3 m length

1005559

  • pk_1_126

Downloads for Suction Lances, Suction Assemblies and Level Switches for Low-Pressure Metering Pumps

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

The right kits for every metering task

The suction lance is installed at the lower end of the suction hose. It fixes the hose in the tank. This is particularly useful when there is a stirrer in the dosing tank. At the end of the suction lance is a foot valve with filter mesh. This protects the suction line from large particles and contaminants.

Suction assemblies are available with or without level monitoring.

The level switch signals the liquid level of the storage tank. In one-stage versions it transmits the signal when the tank is empty. In two-stage versions it also issues a warning before the tank is empty.

The benefits for you

  • Fixes the suction hose
  • Protects against large dirt particles and contamination
  • Signals the empty message of the supply tank
  • Signals the liquid level of the supply tank

Technical Data

Downloads

Contact us

Wesley Sutton

Managing Director, ProMinent Fluid Controls UK Ltd.

»We are always available to help. Don't hesitate to contact us.«

+44 1530 560 555  Send request   

Matching Products

News and Events

ProMinent Newsletter - receive latest news, customized for you! subscribe now