Suggestions

Metering Monitor for Low-Pressure Metering Pumps

Monitoring of the individual strokes in accordance with the float principle.

Product description

Monitoring the metering process

The dosing monitor identifies the most frequent causes of metering errors, such as overpressure, cavitation The formation of small gas bubbles in a fluid. more in the glossary, air bubbles or faulty valves.

Dosing monitors are available for discharge side and suction side installation.

The benefits for you

  • Detects metering errors
  • Issues alarm
  • Can be used on discharge side or suction side

Flow Control Dosing Monitor for Discharge Side Installation

Metering monitor assembly with connector cable for assembly directly on the dosing head to monitor individual strokes based on the float principle. The adjustment screw is used to match the partial flow flowing past the float to the respective stroke volume so that an alarm is emitted if the level is transgressed by approx. 20%. The permitted number of incompletely performed strokes on gamma/ X and gamma/ XL metering pumps can be selected as a figure between 1 to 127, ensuring optimum adaptation to process requirements.

Suitable for metering pumps of the gamma/ X and gamma/ XL product ranges in PP, NP, PV and TT material designs.

Please note: It is essential that you observe the minimum values for the stroke length. The design of the pressure stroke must be set to 'fast'

Note: The metering monitor Flow Control is only suitable for viscosities of less than 100 mPas.

Materials

Housing:PVDF
Float:PTFE-coated
Seals:FKM/EPDM

Flow Control for Discharge Side Installation

Note the minimum values for the stroke length.

Flow Control

For pump type

Material

Order no.

Size I

GMXa 1602

PVDF/EPDM

1009229

Size I

GMXa 1602

PVDF/FKM

1009335

Size II

GMXa 1604-0245, GXLa 1608-0730

PVDF/EPDM

1009336

Size II

GMXa 1604-0245, GXLa 1608-0730

PVDF/FKM

1009338

Pump typeMean operating pressureStroke length (scale division)Maximum permissible operating pressureStroke length (scale division)
16028 bar> 50 %16 bar> 60 %
16045 bar> 30 %16 bar> 50 %
07084 bar> 30 %7 bar> 40 %
10095 bar> 30 %10 bar> 40 %
04142 bar> 30 %4 bar> 30 %
07154 bar> 30 %7 bar> 30 %
02201 bar> 30 %2 bar> 30 %
04242 bar> 30 %4 bar> 30 %

  • pk_1_086_2

Flow Control Dosing Monitor for Installation on Suction Side

Individual strokes are detected on the suction side where the flow velocity is sufficiently high. With water as the medium, the minimum stroke length is 30% and the suction stroke is normal, HV1 or HV2.

Suitable for metering pumps of the gamma/ X and gamma/ XL product ranges with slow compression stroke.

Flow Control

For pump type

Material

Order no.

Size II

GMXa 1604-0245, GXLa 1608-0730

PVDF/EPDM

1036407

Size II

GMXa 1604-0245, GXLa 1608-0730

PVDF/FKM

1036409

Size III

GXLa 0450 – 0280

PVDF/EPDM

1036439

Size III

GXLa 0450 – 0280

PVDF/FKM

1036440

Downloads for Metering Monitor for Low-Pressure Metering Pumps

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

Monitoring the metering process

The dosing monitor identifies the most frequent causes of metering errors, such as overpressure, cavitation The formation of small gas bubbles in a fluid. more in the glossary, air bubbles or faulty valves.

Dosing monitors are available for discharge side and suction side installation.

The benefits for you

  • Detects metering errors
  • Issues alarm
  • Can be used on discharge side or suction side

Technical Data

Downloads

Contact us

Wesley Sutton

Managing Director, ProMinent Fluid Controls UK Ltd.

»We are always available to help. Don't hesitate to contact us.«

+44 1530 560 555  Send request   

Matching Products

News and Events

ProMinent Newsletter - receive latest news, customized for you! subscribe now