Suggestions
new
Automatic chlorine gas metering system DULCO®Vaq

Capacity: 12 g/h - 15 kg/h

The chlorine gas metering system DULCO®Vaq type PM 3610 C for automatically controlled metering of chlorine gas. Its simple operation offers safety and precision in accordance with the current state of technology and in line with DIN standards.

Product description

Maximum safety and precision in chlorine gas metering.

The automatic chlorine gas metering system DULCO®Vaq type PM 3610 C is fitted in the vacuum system between the vacuum controller and injector. The chlorine gas flow is automatically adjusted. A stepper motor controls an ultra-precise V-nozzle, enabling a linear control characteristic over a wide range. Control is by means of external control, such as analogue signals, 0/2 - 10 V, Modbus or by manually setting on the device’s keypad. Opening and operating statuses are signalled externally by analogue and digital outputs and by LEDs on the device. In the event of power failure, the valve closes automatically, although mechanical manual operation is possible. The flow of chlorine gas is displayed on a long-scale flow meter and is held constant by the integrated differential pressure regulator even with fluctuating pressure conditions.

Manometers display both the injector vacuum as well as the operating vacuum.

The entire system is ready-wired and mounted on a PVC panel and protected by an appropriate cover.

Your benefits

  • Automatic chlorine gas metering
  • Plug and Play
  • DIN 19606-compliant
  • Panel-mounted system
  • Wide-ranging controllable motorised control valve
  • Functional cover hood

Field of application

  • Potable water
  • Swimming pool
  • Waste water
  • Cooling water

    Technical Details

    Full vacuum chlorine gas metering system Type PM 3610 C including:

    • Motor control valve PM 3531 C, capacity up to 15 kg/h with V-control nozzle with 1:20 adjustability, with automatic, proportional metering via 4-20 mA signal.
    • LED indicator for opening status
    • 5-Point calibration
    • Simple manual or automatic operation
    • Potential-free contact for error reporting
    • Large-scale flow meter (165 mm) to an accuracy of ± 4 %
    • Differential pressure regulator in conformity with DIN 19606
    • Manometer for displaying operating vacuum
    • Manometer for displaying injector vacuum
    • Non-return valve at the outlet
    • Power supply: 230 VAC 50/60 Hz
    • Vacuum switch optional

    Technical Data

    Dimensions:896 x 396 x 210 mm
    Weight:6.5 kg
    CapacityOrder no.
    kg/h
    Chlorine gas metering system PM3610C/5UDP0.51082492
    Chlorine gas metering system PM3610C/6UDP11082493
    Chlorine gas metering system PM3610C/7UDP21082504
    Chlorine gas metering system PM3610C/8UDP41082505
    Chlorine gas metering system PM3610C/9UDP101083574
    Chlorine gas metering system PM3610C/15UDP151083575

    Downloads for Automatic chlorine gas metering system DULCO®Vaq

    More in the Download Centre

    0 Results
    Filter by document type
    Application Example / Reference (0)
    Brochure / Flyer (0)
    Catalogue (0)
    Certificate / Declaration (0)
    Data Sheet (0)
    Drawing / Dimensional Drawing / 3D (0)
    Exploded View / Spare Parts (0)
    Material Safety Data Sheet (0)
    Operating Instructions (0)
    Others (0)
    Press Release (0)
    Publication / Article (0)
    Software (0)
    Wiring Diagram (0)

    Selected filters:

    Matching downloads

    Sort by A to Z
    Load more matches ...
    No more matches available!

    Leider haben wir kein passendes Suchergebnis gefunden.

    Alle Wörter richtig geschrieben?
    Mit weniger oder anderen Suchbegriffen erneut versuchen?

    Please try again later

    Service Unavailable

    The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

    Overview

    Maximum safety and precision in chlorine gas metering.

    The automatic chlorine gas metering system DULCO®Vaq type PM 3610 C is fitted in the vacuum system between the vacuum controller and injector. The chlorine gas flow is automatically adjusted. A stepper motor controls an ultra-precise V-nozzle, enabling a linear control characteristic over a wide range. Control is by means of external control, such as analogue signals, 0/2 - 10 V, Modbus or by manually setting on the device’s keypad. Opening and operating statuses are signalled externally by analogue and digital outputs and by LEDs on the device. In the event of power failure, the valve closes automatically, although mechanical manual operation is possible. The flow of chlorine gas is displayed on a long-scale flow meter and is held constant by the integrated differential pressure regulator even with fluctuating pressure conditions.

    Manometers display both the injector vacuum as well as the operating vacuum.

    The entire system is ready-wired and mounted on a PVC panel and protected by an appropriate cover.

    Your benefits

    • Automatic chlorine gas metering
    • Plug and Play
    • DIN 19606-compliant
    • Panel-mounted system
    • Wide-ranging controllable motorised control valve
    • Functional cover hood

    Application

    Technical Data

    Downloads

    Contact us

    Stephen Ellix

    Managing Director, ProMinent Fluid Controls UK Ltd.

    »We are always available to help. Don't hesitate to contact us.«

    +44 1530 560 555  Send request   

    Close Form

    Your Request

    Personal Information


    Further product +
    Attachment Maximum file size 10 MB
    Upload Next file

    Personal Information


    Please fill in all mandatory fields.
    *Mandatory fields

    Check and Send


    Personal Information:
    Salutation
    Title
    Last name  
    First name  
    Company
    Customer ID
    E-mail address
    Phone
    Street
    House no.
    City  
    Country
    Callback Yes

    Back