Solenoid-Driven Metering Pump beta
Capacity range 0.74 – 32 l/h, 25 – 2 bar
All-purpose solenoid-driven metering pump for metering liquid media in water treatment and chemical processes: Solenoid-driven metering pump beta. Cost-effective, overload-proof and adaptable to existing signal transducers.
Product description
Equipped with all the features and properties for superior process management.
A range of different pump types and material combinations are available for virtually all metering applications. The virtually wear-free solenoid drive guarantees an exceptionally long service life even under maximum load.
Your benefits
- Optional external control via 0/4 – 20 mA and potential-free contacts with pulse step-up and step-down of 64:1 to 1:64
- Simple adjustment of metering capacity via stroke rate and stroke length
- Adaptation to existing signal transducers by external control via potential-free contacts with pulse step-up and step-down
- Suitable for use with almost all liquid chemicals thanks to the available material combinations: PP, PVDF, clear acrylic, PTFE and stainless steel
- Self-bleeding dosing head design in clear acrylic/PVC and PP
- Virtually wear-free solenoid drive: economical and overload-proof
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Metering liquid media in water treatment and chemical processes
Technical Details
- External control via potential-free contacts with pulse step-up and step-down to adapt to existing signal transducers of 64:1 to 1:64
- Optional external control via 0/4 – 20 mA and potential-free contacts with pulse step-up and step-down of 32:1 to 1:32
- Stroke rate adjustment in 10% increments of 10 – 100% corresponds to 18 – 180 strokes/minute
- Continuous stroke length adjustment of 0 – 100% (recommended 30 – 100%)
- Connector for 2-stage level switch
- Wide-range electrical connection: 100 – 230 V, 50/60 Hz
- Optional relay module, can also be retrofitted easily and securely
- Low voltage design 12 – 24 V DC
Technical Data
Pump type | Pump capacity at max. back pressure | Delivery rate at medium back pressure | Stroke rate | Connector size | Suction lift* | Average power consumption | Shipping weight | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
PP, NP, PV, TT | SS | |||||||||||
bar | l/h | ml/stroke | bar | l/h | ml/stroke | Strokes/min | mm | m WC | W | kg | kg | |
* Suction lift with a filled dosing head and filled suction line, with a self-bleeding dosing head with air in the suction line. | ||||||||||||
** Pressure-reduced pump types are available in the pressure stages 4, 7 and 10 bar for special applications, for example in the swimming pool sector. More detailed information is available upon request. | ||||||||||||
*** 25 bar variant only available with a NP or SS dosing head material. | ||||||||||||
**** With stainless steel design, 6 mm connector width. | ||||||||||||
Metering pumps with non-self-bleeding dosing head | ||||||||||||
BT4b 1000 ** | 10 | 0.74 | 0.07 | 5.0 | 0.82 | 0.08 | 180 | 6 x 4 | 6.0 | 7.2 | 2.9 | 3.6 |
BT4b 1601 ** | 16 | 1.1 | 0.10 | 8.0 | 1.4 | 0.13 | 180 | 6 x 4 | 6.0 | 9.6 | 2.9 | 3.6 |
BT4b 1602 ** | 16 | 2.2 | 0.20 | 8.0 | 2.5 | 0.24 | 180 | 6 x 4 | 6.0 | 11.2 | 2.9 | 3.6 |
BT4b 0708 ** | 7 | 7.1 | 0.66 | 3.5 | 8.4 | 0.78 | 180 | 8 x 5 | 4.0 | 15.2 | 3.1 | 3.9 |
BT4b 0220 | 2 | 19.0 | 1.76 | 1.0 | 20.9 | 1.94 | 180 | 12 x 9 | 2.0 | 15.2 | 3.3 | 4.4 |
BT4b 0413 | 4 | 12.3 | 1.14 | 2.0 | 14.2 | 1.31 | 180 | 8 x 5 | 3.0 | 15.2 | 3.1 | 3.9 |
BT4b 1604 ** | 16 | 3.6 | 0.33 | 8.0 | 4.3 | 0.40 | 180 | 6 x 4 | 5.0 | 15.2 | 3.1 | 3.9 |
BT5b 0232 | 2 | 32 | 2.96 | 1.0 | 36.2 | 3.35 | 180 | 12 x 9 | 2.0 | 19.2 | 5.1 | 6.6 |
BT5b 0420 | 4 | 17.1 | 1.58 | 2.0 | 19.1 | 1.77 | 180 | 12 x 9 | 3.0 | 19.2 | 4.7 | 5.8 |
BT5b 0713 | 7 | 11 | 1.02 | 3.5 | 13.1 | 1.21 | 180 | 8 x 5 | 3.0 | 19.2 | 4.5 | 5.3 |
BT5b 1008 | 10 | 6.8 | 0.63 | 5.0 | 8.3 | 0.76 | 180 | 8 x 5 | 3.0 | 19.2 | 4.5 | 5.3 |
BT5b 2504 | 25 *** | 2.9 | 0.27 | 10.0 | 5.0 | 0.46 | 180 | 8 x 4 **** | 4.0 | 19.2 | 4.5 | 5.3 |
Metering pumps with self-degassing dosing head (dosing head design 7) | ||||||||||||
BT4b 1602 ** | 10 | 1.4 | 0.13 | 8.0 | 1.7 | 0.16 | 180 | 6 x 4 | 1.8 | 11.2 | 2.9 | - |
BT4b 1604 ** | 10 | 2.7 | 0.25 | 8.0 | 3.6 | 0.33 | 180 | 6 x 4 | 1.8 | 15.2 | 3.1 | - |
BT4b 0220 | 2 | 16.2 | 1.50 | 1.0 | 18.0 | 1.67 | 180 | 12 x 9 | 2.0 | 15.2 | 3.3 | - |
BT4b 0413 | 4 | 10.8 | 1.00 | 2.0 | 12.6 | 1.17 | 180 | 8 x 5 | 1.8 | 15.2 | 3.1 | - |
BT4b 0708 ** | 7 | 6.6 | 0.61 | 3.5 | 7.5 | 0.69 | 180 | 8 x 5 | 1.8 | 15.2 | 3.1 | - |
BT5b 0713 | 7 | 10.5 | 0.97 | 3.5 | 12.3 | 1.14 | 180 | 8 x 5 | 1.8 | 19.2 | 4.5 | - |
BT5b 0420 | 4 | 15.6 | 1.44 | 2.0 | 17.4 | 1.61 | 180 | 12 x 9 | 1.8 | 19.2 | 4.7 | - |
BT5b 1008 | 10 | 6.3 | 0.58 | 5.0 | 7.5 | 0.69 | 180 | 8 x 5 | 1.8 | 19.2 | 4.5 | - |
beta b metering pumps with dosing heads for higher-viscosity media have a 10 – 20 % lower capacity and are not self-priming with all feed chemicals. G 3/4-DN 10 connector with d 16-DN 10 hose nozzle.
All data calculated with water at 20 °C.
Materials in Contact with the Medium
Identity code of material | Dosing head | Connection on suction/discharge side | Ball seat | Seals | Balls |
---|---|---|---|---|---|
PVT | PVDF | PVDF | PVDF | PTFE | Ceramic |
PPT | Polypropylene | PVDF | PVDF | PTFE | Ceramic |
PPE | Polypropylene | Polypropylene | EPDM | EPDM | Ceramic |
PPB | Polypropylene | Polypropylene | FKM A | FKM A | Ceramic |
NPT | Clear acrylic | PVDF | PVDF | PTFE | Ceramic |
NPE | Clear acrylic | PVC | EPDM | EPDM | Ceramic |
NPB | Clear acrylic | PVC | FKM A | FKM A | Ceramic |
SST | Stainless steel 1.4404 | Stainless steel 1.4404 | Ceramic | PTFE | Ceramic |
TTT | Carbon-filled PTFE | Carbon-filled PTFE | Ceramic | PTFE | Ceramic |
Metering reproducibility: ± 2% when used according to the operating instructions.
Permissible ambient temperature –10 °C to +45 °C.
Degree of protection: IP 66, insulation class F
Scope of supply
Metering pump with mains cable, connector kit for hose/tube connector as per table.
Downloads for Solenoid-Driven Metering Pump beta
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.
Overview
Equipped with all the features and properties for superior process management.
A range of different pump types and material combinations are available for virtually all metering applications. The virtually wear-free solenoid drive guarantees an exceptionally long service life even under maximum load.
Your benefits
- Optional external control via 0/4 – 20 mA and potential-free contacts with pulse step-up and step-down of 64:1 to 1:64
- Simple adjustment of metering capacity via stroke rate and stroke length
- Adaptation to existing signal transducers by external control via potential-free contacts with pulse step-up and step-down
- Suitable for use with almost all liquid chemicals thanks to the available material combinations: PP, PVDF, clear acrylic, PTFE and stainless steel
- Self-bleeding dosing head design in clear acrylic/PVC and PP
- Virtually wear-free solenoid drive: economical and overload-proof
Application
Field of application
The following list of applications are general examples of generally suitable applications for this product. Please contact your local sales representative to talk about the applicable use of this product in your specific case / environment.
- Metering liquid media in water treatment and chemical processes
Technical Data
Technical Details
- External control via potential-free contacts with pulse step-up and step-down to adapt to existing signal transducers of 64:1 to 1:64
- Optional external control via 0/4 – 20 mA and potential-free contacts with pulse step-up and step-down of 32:1 to 1:32
- Stroke rate adjustment in 10% increments of 10 – 100% corresponds to 18 – 180 strokes/minute
- Continuous stroke length adjustment of 0 – 100% (recommended 30 – 100%)
- Connector for 2-stage level switch
- Wide-range electrical connection: 100 – 230 V, 50/60 Hz
- Optional relay module, can also be retrofitted easily and securely
- Low voltage design 12 – 24 V DC
Technical Data
Pump type | Pump capacity at max. back pressure | Delivery rate at medium back pressure | Stroke rate | Connector size | Suction lift* | Average power consumption | Shipping weight | |||||
---|---|---|---|---|---|---|---|---|---|---|---|---|
PP, NP, PV, TT | SS | |||||||||||
bar | l/h | ml/stroke | bar | l/h | ml/stroke | Strokes/min | mm | m WC | W | kg | kg | |
* Suction lift with a filled dosing head and filled suction line, with a self-bleeding dosing head with air in the suction line. | ||||||||||||
** Pressure-reduced pump types are available in the pressure stages 4, 7 and 10 bar for special applications, for example in the swimming pool sector. More detailed information is available upon request. | ||||||||||||
*** 25 bar variant only available with a NP or SS dosing head material. | ||||||||||||
**** With stainless steel design, 6 mm connector width. | ||||||||||||
Metering pumps with non-self-bleeding dosing head | ||||||||||||
BT4b 1000 ** | 10 | 0.74 | 0.07 | 5.0 | 0.82 | 0.08 | 180 | 6 x 4 | 6.0 | 7.2 | 2.9 | 3.6 |
BT4b 1601 ** | 16 | 1.1 | 0.10 | 8.0 | 1.4 | 0.13 | 180 | 6 x 4 | 6.0 | 9.6 | 2.9 | 3.6 |
BT4b 1602 ** | 16 | 2.2 | 0.20 | 8.0 | 2.5 | 0.24 | 180 | 6 x 4 | 6.0 | 11.2 | 2.9 | 3.6 |
BT4b 0708 ** | 7 | 7.1 | 0.66 | 3.5 | 8.4 | 0.78 | 180 | 8 x 5 | 4.0 | 15.2 | 3.1 | 3.9 |
BT4b 0220 | 2 | 19.0 | 1.76 | 1.0 | 20.9 | 1.94 | 180 | 12 x 9 | 2.0 | 15.2 | 3.3 | 4.4 |
BT4b 0413 | 4 | 12.3 | 1.14 | 2.0 | 14.2 | 1.31 | 180 | 8 x 5 | 3.0 | 15.2 | 3.1 | 3.9 |
BT4b 1604 ** | 16 | 3.6 | 0.33 | 8.0 | 4.3 | 0.40 | 180 | 6 x 4 | 5.0 | 15.2 | 3.1 | 3.9 |
BT5b 0232 | 2 | 32 | 2.96 | 1.0 | 36.2 | 3.35 | 180 | 12 x 9 | 2.0 | 19.2 | 5.1 | 6.6 |
BT5b 0420 | 4 | 17.1 | 1.58 | 2.0 | 19.1 | 1.77 | 180 | 12 x 9 | 3.0 | 19.2 | 4.7 | 5.8 |
BT5b 0713 | 7 | 11 | 1.02 | 3.5 | 13.1 | 1.21 | 180 | 8 x 5 | 3.0 | 19.2 | 4.5 | 5.3 |
BT5b 1008 | 10 | 6.8 | 0.63 | 5.0 | 8.3 | 0.76 | 180 | 8 x 5 | 3.0 | 19.2 | 4.5 | 5.3 |
BT5b 2504 | 25 *** | 2.9 | 0.27 | 10.0 | 5.0 | 0.46 | 180 | 8 x 4 **** | 4.0 | 19.2 | 4.5 | 5.3 |
Metering pumps with self-degassing dosing head (dosing head design 7) | ||||||||||||
BT4b 1602 ** | 10 | 1.4 | 0.13 | 8.0 | 1.7 | 0.16 | 180 | 6 x 4 | 1.8 | 11.2 | 2.9 | - |
BT4b 1604 ** | 10 | 2.7 | 0.25 | 8.0 | 3.6 | 0.33 | 180 | 6 x 4 | 1.8 | 15.2 | 3.1 | - |
BT4b 0220 | 2 | 16.2 | 1.50 | 1.0 | 18.0 | 1.67 | 180 | 12 x 9 | 2.0 | 15.2 | 3.3 | - |
BT4b 0413 | 4 | 10.8 | 1.00 | 2.0 | 12.6 | 1.17 | 180 | 8 x 5 | 1.8 | 15.2 | 3.1 | - |
BT4b 0708 ** | 7 | 6.6 | 0.61 | 3.5 | 7.5 | 0.69 | 180 | 8 x 5 | 1.8 | 15.2 | 3.1 | - |
BT5b 0713 | 7 | 10.5 | 0.97 | 3.5 | 12.3 | 1.14 | 180 | 8 x 5 | 1.8 | 19.2 | 4.5 | - |
BT5b 0420 | 4 | 15.6 | 1.44 | 2.0 | 17.4 | 1.61 | 180 | 12 x 9 | 1.8 | 19.2 | 4.7 | - |
BT5b 1008 | 10 | 6.3 | 0.58 | 5.0 | 7.5 | 0.69 | 180 | 8 x 5 | 1.8 | 19.2 | 4.5 | - |
beta b metering pumps with dosing heads for higher-viscosity media have a 10 – 20 % lower capacity and are not self-priming with all feed chemicals. G 3/4-DN 10 connector with d 16-DN 10 hose nozzle.
All data calculated with water at 20 °C.
Materials in Contact with the Medium
Identity code of material | Dosing head | Connection on suction/discharge side | Ball seat | Seals | Balls |
---|---|---|---|---|---|
PVT | PVDF | PVDF | PVDF | PTFE | Ceramic |
PPT | Polypropylene | PVDF | PVDF | PTFE | Ceramic |
PPE | Polypropylene | Polypropylene | EPDM | EPDM | Ceramic |
PPB | Polypropylene | Polypropylene | FKM A | FKM A | Ceramic |
NPT | Clear acrylic | PVDF | PVDF | PTFE | Ceramic |
NPE | Clear acrylic | PVC | EPDM | EPDM | Ceramic |
NPB | Clear acrylic | PVC | FKM A | FKM A | Ceramic |
SST | Stainless steel 1.4404 | Stainless steel 1.4404 | Ceramic | PTFE | Ceramic |
TTT | Carbon-filled PTFE | Carbon-filled PTFE | Ceramic | PTFE | Ceramic |
Metering reproducibility: ± 2% when used according to the operating instructions.
Permissible ambient temperature –10 °C to +45 °C.
Degree of protection: IP 66, insulation class F
Scope of supply
Metering pump with mains cable, connector kit for hose/tube connector as per table.
Downloads
Downloads for Solenoid-Driven Metering Pump beta
Service Unavailable
The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.