Suggestions

Transmitter DULCOMETER DMTa

The transmitter DULCOMETER DMTa converts the sensor signals for pH, ORP value, chlorine concentration and conductivity into an interference-insensitive 4-20 mA analogue signal. Flexible, safe and always the optimum resolution of measured value.

Product description

The compact 2-wire transmitter – the link to the PLC and DULCOMETER.

The 2-wire transmitter DMTa converts the following sensor signals into an interference-insensitive 4-20 mA analogue signal: pH, ORP, temperature, chlorine and conductivity.

It is fed via the 2-wire analogue input of a PLC or via a 2-wire analogue input of a ProMinent controller. The 4-20 mA analogue current proportional to the measured value is transmitted via the same two lines.

The DMTa offers an on-site calibration When a metering pump has been installed, the capacity in litres per hour has to be determined under ... more in the glossary option of the sensor and galvanic separation between the sensor input and measured value output.

Your benefits

  • Flexibility in the choice of measured variable with pH, ORP and temperature
  • Excellent operational safety, thanks to sensor monitoring (pH)
  • Galvanic isolation between the sensor and supply
  • Always the optimum measured value resolution by auto-ranging with conductivity measurement
  • Safety through sensor monitoring of pH for glass breakage and line breakage
  • Various installation options: wall-mounted, installation on an upright or in a control cabinet

Technical Details

  • Measured variables: pH, ORP, chlorine, temperature and conductivity
  • Precision: 0.5 % of the measuring range limit value
  • Correction variable: Temperature via Pt 100/Pt 1000 (pH, chlorine, conductivity)
  • Communication interface: PROFIBUS DP (wall-mounted only)
  • Degree of protection: IP 65 (wall-mounted, pipe-mounted), IP 54 (installation in a control cabinet)
  • Display: Graphic display

Technical Data

Measuring range

pH - 1.00 … 15.00
-1200 … +1200 mV redox potential
0.01 … 50.0 mg/l Chlorine
-20 … +150 °C
1 µS/cm … 200 mS/cm (auto-ranging), depending on the cell constant

Cell constant

0.006 … 12.0/cm for conductivity

Resolution

0.01 pH
1 mV
0.1 % of measuring range for chlorine
0.1 °C
Conductivity 1/1000 of display value (min. 0.001 μS/cm)

Accuracy

0.5% from measurement range

Measurement input

mV terminal (pH, ORP); input resistance > 5 x 1011 Ω
Chlorine terminal (DMT chlorine sensors)
Pt 100/1000 terminal
Conductivity terminal (2 or 4-line connection)

Correction variable

Temperature via Pt 100/1000 (pH, chlorine, conductivity)

Correction range temp.

Chlorine: 5 … 45 °C, pH: 0 … 100 °C, conductivity: 0 … 100 °C

Min. current loop

4 mA

Max. current loop

20 mA

Fault current

23 mA

Feed voltage

2-wire transmitter, 16... 35 V DC, nominal 24 V
PROFIBUS DP design, 16... 30 V DC, 24 V nominal

Communication interface

PROFIBUS DP (wall-mounted only)

Min. ambient temperature

0 °C

Max. ambient temperature

55 °C

Climate

Relative humidity up to 95% (non-condensing)

Enclosure rating

IP 65 (wall-mounted, pipe-mounted)
IP 54 (installation in a control cabinet)

Display

graphical display

Housing material

PPE

Dim. H

135 mm

Dim. B

125 mm

D dimension

75 mm

Weight

0.45 kg

Downloads for Transmitter DULCOMETER DMTa

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

The compact 2-wire transmitter – the link to the PLC and DULCOMETER.

The 2-wire transmitter DMTa converts the following sensor signals into an interference-insensitive 4-20 mA analogue signal: pH, ORP, temperature, chlorine and conductivity.

It is fed via the 2-wire analogue input of a PLC or via a 2-wire analogue input of a ProMinent controller. The 4-20 mA analogue current proportional to the measured value is transmitted via the same two lines.

The DMTa offers an on-site calibration When a metering pump has been installed, the capacity in litres per hour has to be determined under ... more in the glossary option of the sensor and galvanic separation between the sensor input and measured value output.

Your benefits

  • Flexibility in the choice of measured variable with pH, ORP and temperature
  • Excellent operational safety, thanks to sensor monitoring (pH)
  • Galvanic isolation between the sensor and supply
  • Always the optimum measured value resolution by auto-ranging with conductivity measurement
  • Safety through sensor monitoring of pH for glass breakage and line breakage
  • Various installation options: wall-mounted, installation on an upright or in a control cabinet

Application

Technical Data

Downloads

Contact us

Wesley Sutton

Managing Director, ProMinent Fluid Controls UK Ltd.

»We are always available to help. Don't hesitate to contact us.«

+44 1530 560 555  Send request   

Matching Products

The peristaltic pump DULCOFLEX DF2a meters chemicals functionally, cost-effectively and quietly – ideal for use in swimming pools, hot tubs, and in spa and wellness facilities.

more

The peristaltic pump DULCOFLEX DF4a for metering flocculants and activated charcoal treats water precisely and accurately. It is ideal for use in swimming pools, hot tubs or spa and wellness facilities. An operating pressure up to 4 bar is possible.

more

The controller DULCOMETER D1Cb/D1Cc can be used for control tasks in potable water treatment, wastewater treatment and many other areas. Safe, convenient and clear, thanks to the large illuminated graphic display, plain text operating menu and pH sensor monitoring.

more

The measuring and control system DULCOMARIN 3 is your digital link to the technology of the future. It controls the entire range of swimming pools – from adventure pools to private pools – and is used as a multi-pool system for up to 16 filter circuits.

more

Photometers measure nearly all disinfectants and the pH value based on the photometric principle. They are portable, compact and make safe, simple measurement possible.

more

As a nanofiltration system, the DULCOSMOSE NF, a compact and value-for-money unit, can handle partial desalination in industrial applications. Maximum permeate output at low operating pressures ensures low operating costs thanks to the "ultra low pressure" diaphragm.

more

Ultrafiltration system DULCOCLEAN UF reliably and safely uses membrane technology to remove turbidity, particles and microbiological contamination.

more

ORP measurements with DULCOTEST sensors: Precise, reliable and application-adapted measured values in real-time. Can be used in water treatment or industrial process waters with strict requirements.

more

Chlorine dioxide measurement with DULCOTEST sensors offers precise, reliable, application-specific measured values in real-time for all oxidation and disinfection tasks.

more

The application-based DULCOTEST sensors for free chlorine deliver precise measured values and a high degree of monitoring and process reliability in any disinfection application.

more

Disinfection of swimming pool water with the application-optimised DULCOTEST sensors for total available chlorine - exact measured values and high process reliability guaranteed.

more

Reliably measure total chlorine with the versatile DULCOTEST sensors for total chlorine. Accurate measured values and a high degree of monitoring and process reliability are guaranteed.

more

Temperature measurement with DULCOTEST sensors: Can be used for direct temperature measurement or temperature compensation during measurement of pH, fluoride, conductivity, chlorine dioxide or hydrogen peroxide.

more

Conductivity sensors for optimum process integration: DULCOTEST sensors meet a wide range of measuring requirements and allow the best solution to any given measuring task to be achieved.

more

ProMinent Newsletter - receive latest news, customized for you! subscribe now