Suggestions

Controller DULCOMETER diaLog X

The DULCOMETER diaLog X multi-parameter controller ensures that complex water treatment systems are operated as efficiently as possible. The controller is highly flexible and suitable for many sensor parameters.

Product description

From small to large - extremely flexible for all water treatment systems

Application-specific software modules are available for the DULCOMETER diaLog X to make configuration to the process as simple and precise as possible, without the need for programming. Using freely configurable function blocks, the DULCOMETER diaLog X can map almost any customer application.

The controller is scalable and manages several systems simultaneously and decentrally. The combination of main and satellite unit increases flexibility. The main unit can be extended by up to two satellite units. This makes the DULCOMETER diaLog X suitable for almost all customer applications in water treatment, even on a large scale.

The system can be conveniently controlled remotely thanks to the wide range of communication options. A customisable web server A web server is a software application executed by the DULCOMARIN® II. more in the glossary enables easy management, tracking and visualisation of data, even remotely by DULCONNEX.

Your benefits

  • Excellent flexibility thanks to modular construction and easily extendible IO modules (input/output), allowing more sensors and pumps to be connected.
  • Up to two satellite units can be added for additional inputs and outputs, allowing more sensors and pumps to be connected.
  • Intuitive operation via the HMI (Human-Machine Interface) thanks to a clearly legible industrial display and robust keys for standard commands, such as calibration and monitoring.
  • Simple configuration of process settings as well as monitoring and visualisation of process data via a web server with freely configurable and preconfigured software modules.
  • Extensive overview and control of processes, e.g. cooling tower processes: All process data and alarms can be communicated to the process control system via fieldbuses such as Modbus RTU.
  • Advanced communication options: Various network protocols such as FTP or MQTT enable remote access and data management via Wi-Fi and LAN (Ethernet).

Technical Details

Comprehensive inputs and outputs

  • Up to 24 flexible sensor inputs and mA outputs (8 per device), e.g. CTFS sensor, linear polarisation resistor (LPR) corrosion sensor
  • Up to 30 output relays and pulse outputs (10 per device) to control pumps and other actuators
  • Up to 24 digital inputs (8 per device) to control level switches, water meters and remote switches
  • Up to 12 pulse frequency outputs
  • Up to 18 relays

Communication options

  • In-built Modbus RTU and via gateways (BACnet, Modbus TCP, PROFINET)
  • Web interface via Wi-Fi and Ethernet, FTP server, rest API, MQTT client interface. The client interface is an intuitive remote control via a Wi-Fi or network connection to your PC or smartphone, e.g. for configuration settings or setpoint settings.
  • Configurable and managed via DULCONNEX.

Technical Data

Measured variables and measuring ranges

Conductivity:
with the digital sensor CTFS: 0.1 - 10 mS/cm
Via conductivity module L3 depending on sensor used (LMP, LFT): 50 μS cm - 20 mS/cm
Via mA module AA with the inductive conductivity sensor ICT: 8 to 2 mS/cm, 20 mS/cm, 200 mS/cm
Type of connection mV:
pH: 0.00 ... 14.00
ORP potential: -1500 ... +1500 mV
Type of connection mA (amperometric measured variables, measuring ranges corresponding to sensors, 2 ppm, 10 ppm):
Chlorine
Chlorine dioxide
Chlorite
Bromine
Ozone
Hydrogen peroxide
Peracetic acid
Temperature:
via Pt 100/Pt 1000, measuring range 0 ... 150 °C

Inputs and outputs

Inputs
4 plug-in module slots per unit for
2-channel serial sensor input module
2-channel conductivity input module
2-channel mV input module
2-channel mV/mA input module
2-channel mA input module
Outputs
2-channel mA output module
6 output relays as changeover contacts, of which 3 are potential-free and 3 are AC/DC
4 pulse frequency outputs for controlling metering pumps
8 digital control inputs for contact water meter, flow switch and pause for locking

Resolution

pH: 0.01 pH
ORP: 1 mV
Amperometric analysis (chlorine etc.): 0.001/0.01 ppm, 0.01 vol. %

Accuracy

0.3% based on the full-scale reading

Temperature compensation

Pt 100/Pt 1000 for pH

Control characteristic

P/PI/PID control

Electrical Connection

100 – 230 V, 50/60 Hz

Ambient temperature

-5 … 50 °C at max. 95% relative air humidity (non-condensing)

Tests and approvals

CE, MET, UK CA

Housing material

PC with flameproofing equipment

Dimensions

276 x 424 x 137 mm (H x W x D)

Enclosure rating

Wall-mounted: IP 67

Field bus connection

Modbus RTU, additional field buses via gateway

Downloads for Controller DULCOMETER diaLog X

More in the Download Centre

0 Results
Filter by document type
Application Example / Reference (0)
Brochure / Flyer (0)
Catalogue (0)
Certificate / Declaration (0)
Data Sheet (0)
Drawing / Dimensional Drawing / 3D (0)
Exploded View / Spare Parts (0)
Material Safety Data Sheet (0)
Operating Instructions (0)
Others (0)
Press Release (0)
Publication / Article (0)
Software (0)
Wiring Diagram (0)

Selected filters:

Matching downloads

Sort by Document type
Load more matches ...
No more matches available!

Unfortunately, we did not find an appropriate match.

All words written correctly?
Search again with fewer or different search terms?

Please try again later

Service Unavailable

The server is temporarily unable to service your request due to maintenance downtime or capacity problems. Please try again later.

Overview

From small to large - extremely flexible for all water treatment systems

Application-specific software modules are available for the DULCOMETER diaLog X to make configuration to the process as simple and precise as possible, without the need for programming. Using freely configurable function blocks, the DULCOMETER diaLog X can map almost any customer application.

The controller is scalable and manages several systems simultaneously and decentrally. The combination of main and satellite unit increases flexibility. The main unit can be extended by up to two satellite units. This makes the DULCOMETER diaLog X suitable for almost all customer applications in water treatment, even on a large scale.

The system can be conveniently controlled remotely thanks to the wide range of communication options. A customisable web server A web server is a software application executed by the DULCOMARIN® II. more in the glossary enables easy management, tracking and visualisation of data, even remotely by DULCONNEX.

Your benefits

  • Excellent flexibility thanks to modular construction and easily extendible IO modules (input/output), allowing more sensors and pumps to be connected.
  • Up to two satellite units can be added for additional inputs and outputs, allowing more sensors and pumps to be connected.
  • Intuitive operation via the HMI (Human-Machine Interface) thanks to a clearly legible industrial display and robust keys for standard commands, such as calibration and monitoring.
  • Simple configuration of process settings as well as monitoring and visualisation of process data via a web server with freely configurable and preconfigured software modules.
  • Extensive overview and control of processes, e.g. cooling tower processes: All process data and alarms can be communicated to the process control system via fieldbuses such as Modbus RTU.
  • Advanced communication options: Various network protocols such as FTP or MQTT enable remote access and data management via Wi-Fi and LAN (Ethernet).

Application

Technical Data

Downloads

Contact us

Wesley Sutton

Managing Director, ProMinent Fluid Controls UK Ltd.

»We are always available to help. Don't hesitate to contact us.«

+44 1530 560 555  Send request   

ProMinent Newsletter - receive latest news, customized for you! subscribe now